Cardiac Mapping Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
16
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 26 publications
(16 citation statements)
references
References 45 publications
0
16
0
Order By: Relevance
“…Minimizing radiation exposure during these procedures can minimize the risks, including malignancies, especially to the physicians and laboratory staff. There is enough evidence that minimizing or eliminating radiation use during electrophysiology procedures is safe and effective 6‐8 …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Minimizing radiation exposure during these procedures can minimize the risks, including malignancies, especially to the physicians and laboratory staff. There is enough evidence that minimizing or eliminating radiation use during electrophysiology procedures is safe and effective 6‐8 …”
Section: Discussionmentioning
confidence: 99%
“…5 There are three 3D EAM systems now in common clinical use: the Carto system (Biosense Webster, USA), the EnSite system (Abbott, USA), and the Rhythmia (Boston Scientific, USA). 6 Over the years, we have seen a significant improvement in the technology of 3D EAM and the procedural skills of electrophysiologists, which has allowed for minimizing or eliminating the use of fluoroscopy during various electrophysiology procedures. 7,8 Minimizing radiation exposure during these procedures can minimize the risks, including malignancies, especially to the physicians and laboratory staff.…”
Section: Discussionmentioning
confidence: 99%
“…These currents are injected from orthogonal electrode pairs and allows for co-localization of the catheter tip based on the resulting potential difference in the recording tip with respect to a reference electrode. Unlike CARTO, with Ensite the chamber geometry can be determined with any catheter with an electrode, and any catheter can be utilized for mapping and recording of intracardiac signals for the voltage and activation map [20,21], which is timed against a fiducial point on reference catheter (similar to CARTO). Advanced activation noncontact mapping is available in some systems and utilizes a multi-electrode mesh that is mounted on a balloon and positioned in the cardiac chamber of interest.…”
Section: D Electroanatomic Mappingmentioning
confidence: 99%
“…Advanced activation noncontact mapping is available in some systems and utilizes a multi-electrode mesh that is mounted on a balloon and positioned in the cardiac chamber of interest. Without actually contacting the endocardial surface, myocardial potentials can be reconstructed by recording the cavity potentials allowing for indirect reconstruction of the endocardial potentials and activation patterns [20][21][22].…”
Section: D Electroanatomic Mappingmentioning
confidence: 99%
See 1 more Smart Citation