2019
DOI: 10.1016/j.ccep.2018.11.007
|View full text |Cite
|
Sign up to set email alerts
|

Cardiac Magnetic Resonance as a Tool to Assess Dyssynchrony

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 29 publications
0
5
0
1
Order By: Relevance
“…Cardiac dyssynchrony. 25 Along with the new echocardiographic modalities, Cardiac MRI is useful for the study of cardiac synchrony and dyssynchrony; however, to date this study should not be considered as a major selection criterion for deciding cardiac resynchronization therapy. c.3.…”
Section: Noninvasive Cardiovascular Imagingmentioning
confidence: 99%
See 1 more Smart Citation
“…Cardiac dyssynchrony. 25 Along with the new echocardiographic modalities, Cardiac MRI is useful for the study of cardiac synchrony and dyssynchrony; however, to date this study should not be considered as a major selection criterion for deciding cardiac resynchronization therapy. c.3.…”
Section: Noninvasive Cardiovascular Imagingmentioning
confidence: 99%
“…25 mg every 12 hours, bisoprolol 2.5 mg every 24 hours, metoprolol succinate 50 mg every 24 hours, nevibolol 2.5 mg every 24 hours Dose 1 Carvedilol 25 mg every 12 hours, bisoprolol 10 mg every 24 hours, metoprolol succinate 200 mg every 24 hours, nevibolol 10 mg every 24hrs Dose 2 Carvedilol 12.5 mg every 12 hours, bisoprolol 5 mg every 24 hours, metoprolol succinate 100 mg every 24 hours, nevibolol 5 mg every 24 hours Dose 3…”
mentioning
confidence: 99%
“…The main disadvantages include long acquisition and breath-hold times. DENSE is a highly sophisticated tool in assessing dyssynchrony by direct strain measurement with high spatial resolution and improved temporal resolution [12,13].…”
Section: Evaluation Of Mechanical Dyssynchrony By Cardiac Magnetic Rementioning
confidence: 99%
“…However, mechanical dyssynchrony can also be measured using cardiac magnetic resonance (CMR). CMR can provide high-resolution strain images to assess dyssynchrony with reduced inter-observer variability 59). The myocardial tagging technique is the most commonly used, but the recently developed cine displacement encoding with stimulated echoes methodology provides accurate assessment of myocardial displacement and circumferential strain with higher resolution 59).…”
Section: The Optimization Of Cardiac Resynchronization Therapymentioning
confidence: 99%
“…CMR can provide high-resolution strain images to assess dyssynchrony with reduced inter-observer variability 59). The myocardial tagging technique is the most commonly used, but the recently developed cine displacement encoding with stimulated echoes methodology provides accurate assessment of myocardial displacement and circumferential strain with higher resolution 59). However, the techniques for assessing dyssynchrony with CMR still remain mostly for research purposes, and large, prospective, multicenter trials of clinically feasible external validation have not been undertaken to evaluate their performance.…”
Section: The Optimization Of Cardiac Resynchronization Therapymentioning
confidence: 99%