2017
DOI: 10.22468/cvia.2016.00101
|View full text |Cite
|
Sign up to set email alerts
|

Cardiac Implantable Electronic Devices and Magnetic Resonance Imaging

Abstract: Magnetic resonance imaging (MRI) is an excellent body imaging modality. One limitation of MRI is that the physical environment may be a risk for patients with implantable metallic devices. In the past, a cardiac implantable electronic device (CIED) was an absolute MRI contraindication. However, since the introduction of MRI-conditional CIED, the indication for MRI examination has progressed significantly. Cardiac magnetic resonance (CMR) examination can also be performed restrictively in patients with MRI-cond… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…This challenge is mainly seen during imaging of the thorax and the heart when a CIED is in situ. The ferromagnetic components in CIED's may produce susceptibility artifacts and signal void during MRI 68,69 potentially causing a poor‐quality image 30,70 …”
Section: Interaction Of Mri With Ciedmentioning
confidence: 99%
See 3 more Smart Citations
“…This challenge is mainly seen during imaging of the thorax and the heart when a CIED is in situ. The ferromagnetic components in CIED's may produce susceptibility artifacts and signal void during MRI 68,69 potentially causing a poor‐quality image 30,70 …”
Section: Interaction Of Mri With Ciedmentioning
confidence: 99%
“…Susceptibility artifacts are the distortion of the images in gradient sequences owing to the high magnetic susceptibility of the ferromagnetic substances in the CIED leads causing signal loss and dephasing at the tissue lead interphase. Magnetization causes inhomogeneities leading to the dephasing artifact 68,71–73 …”
Section: Interaction Of Mri With Ciedmentioning
confidence: 99%
See 2 more Smart Citations
“…2 The main components of a CIED in contact with the patients tissues are the pulse generator encasing (made from titanium), the connector head (made from a polymer) and the leads. 3 The materials used to make each of these components varies slightly depending on the manufacturer and type of device.Hypersensitivity reactions (HSR) to metals and epoxies have been reported in orthopaedic, vascular neurosurgical and interventional cardiology in the form of coronary and vascular stents and endovascular occluder devices. [4][5][6][7] HSRs to components of CIEDs are thought to be a rare complication.…”
mentioning
confidence: 99%