2008
DOI: 10.1002/elan.200704176
|View full text |Cite
|
Sign up to set email alerts
|

Carbon Paste Electrode Incorporating 1‐[4‐(Ferrocenyl Ethynyl) Phenyl]‐1‐Ethanone for Electrocatalytic and Voltammetric Determination of Tryptophan

Abstract: A carbon paste electrode spiked with 1-[4-ferrocenyl ethynyl) phenyl]-1-ethanone (4FEPE) was constructed by incorporation of 4FEPE in graphite powder-paraffin oil matrix. It has been shown by direct current cyclic voltammetry and double step chronoamperometry that this electrode can catalyze the oxidation of tryptophan (Trp) in aqueous buffered solution. It has been found that under optimum condition (pH 7.00), the oxidation of Trp at the surface of such an electrode occurs at a potential about 200 mV less pos… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
67
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
10

Relationship

3
7

Authors

Journals

citations
Cited by 144 publications
(69 citation statements)
references
References 15 publications
2
67
0
Order By: Relevance
“…In addition, the value of α was calculated for the oxidation of CA at pH 7.0 for the MWCNTPE in both the absence and presence of mediator using the following equation, 34,35 αn α = 0.048/(E P -E P/2 )…”
Section: Catalytic Effectmentioning
confidence: 99%
“…In addition, the value of α was calculated for the oxidation of CA at pH 7.0 for the MWCNTPE in both the absence and presence of mediator using the following equation, 34,35 αn α = 0.048/(E P -E P/2 )…”
Section: Catalytic Effectmentioning
confidence: 99%
“…A linear response was obtained in the concentration range 1-5.9 × 10 −5 M as well as 2-8 × 10 −3 M. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.4 × 10 −5 M and 2.29 × 10 −5 M respectively for the lower end calibration graph. Modified CPE showed the linear range and detection limit comparable [25,26] and better [51][52][53] than the reported electrochemical methods.…”
Section: Discussionmentioning
confidence: 80%
“…This method has been used for estimating the value of k h for some compounds. [20][21][22][23] The effect of solution pH on electrochemical responses of benserazide and/or levodopa at the surface of CAMCPE was investigated over a pH range of 6.5 to 10.5 using cyclic voltammetry. Figure 6 shows the variation in ΔI pa versus pH.…”
Section: Influence Of Variablesmentioning
confidence: 99%