2015
DOI: 10.1016/j.foodchem.2014.10.106
|View full text |Cite
|
Sign up to set email alerts
|

Carbon nanotubes for voltammetric determination of sulphite in some beverages

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
22
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 65 publications
(23 citation statements)
references
References 32 publications
(55 reference statements)
0
22
0
1
Order By: Relevance
“…Figure 8B illustrates the DPV signals obtained by measuring 50 µM of NFT which is stored at room temperature. The results disclose that a reduction peak current response is only 3% even after a week which continued till one month, stating good storage capability of the proposed sensor 44,45 . Continuing, to the proposed sensor NiFe/f-MWCNT is checked with 8 multiple measurements using a similar electrode for better repeatability enhancement analysis.…”
Section: Effect Of Ph Concentration and Scan Rate For Nftmentioning
confidence: 86%
“…Figure 8B illustrates the DPV signals obtained by measuring 50 µM of NFT which is stored at room temperature. The results disclose that a reduction peak current response is only 3% even after a week which continued till one month, stating good storage capability of the proposed sensor 44,45 . Continuing, to the proposed sensor NiFe/f-MWCNT is checked with 8 multiple measurements using a similar electrode for better repeatability enhancement analysis.…”
Section: Effect Of Ph Concentration and Scan Rate For Nftmentioning
confidence: 86%
“…The LOD was 0.06 mg/kg expressed as sulfur dioxide. Silva et al (2015) presented a squarewave voltammetric method based on sulfite electrochemical reduction using a carbon-paste electrode chemically modified with multiwalled carbon nanotubes for the quantification of sulfites in commercial beverages. The method is not applicable to red grape juice or red wine samples.…”
Section: Flow Injection Analysis (Fia)mentioning
confidence: 99%
“…This electrode has a 0.6 µM detection limit and a strong anti-interference ability. On the other hand, carbon paste electrodes modified with carbon nanotubes 19 were used for voltammetric detection of sulfite in commercial beverages with a limit of detection of 1.0 mg SO 2 L -1 . On the other hand, glassy carbon electrodes modified with switching structures of praseodynium hexacyanoferrate show very good electrocatalytic behavior toward the oxidation of sulfite 20 .…”
Section: Introductionmentioning
confidence: 99%