2020
DOI: 10.1016/j.jcis.2020.06.034
|View full text |Cite
|
Sign up to set email alerts
|

Carbon dots derived from flax straw for highly sensitive and selective detections of cobalt, chromium, and ascorbic acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
45
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 123 publications
(50 citation statements)
references
References 52 publications
2
45
0
Order By: Relevance
“…The limit of detection (LOD) of Cr(VI) was estimated to be 1.04 mM according to the formula (LOD ¼ 3s/S, wherein s is the standard deviation of the blank signals, S represents the slope of the linear curve). 46 Compared with the previous reported literatures presented in Table S1, † the N,S-CDs in this work expressed better detection performance for Cr(VI). Based on the excellent performance, the N,S-CDs as a "turn-off" uorescent sensor own unique superiorities of sensitivity, selectivity, convenience, green preparation, stability, fast response, origin from renewable resources, etc.…”
Section: Detection Of Cr(vi)supporting
confidence: 38%
“…The limit of detection (LOD) of Cr(VI) was estimated to be 1.04 mM according to the formula (LOD ¼ 3s/S, wherein s is the standard deviation of the blank signals, S represents the slope of the linear curve). 46 Compared with the previous reported literatures presented in Table S1, † the N,S-CDs in this work expressed better detection performance for Cr(VI). Based on the excellent performance, the N,S-CDs as a "turn-off" uorescent sensor own unique superiorities of sensitivity, selectivity, convenience, green preparation, stability, fast response, origin from renewable resources, etc.…”
Section: Detection Of Cr(vi)supporting
confidence: 38%
“…In addition, benefiting from the dual-model response to pH changing as well as the established analytical method, wound pH could be both predicted theoretically and estimated visually in the case of blood contamination and long-term observations. Besides applications in ions and pH sensing, CDs also show selectivity toward a wide range of biomolecules including amino acids (such as cysteine), glutathione, vitamins (such as vitamin B 12 , vitamin B 7 , ascorbic acid), formaldehyde, glucose, DNA, and proteins, , which are associated with health issues and diseases. Therefore, CDs can provide valuable insights into the diagnostics and early precaution of diseases.…”
Section: Optical Applicationsmentioning
confidence: 99%
“…Both the quenching constants for the Fe 3+ and AA were one or two orders of magnitude higher than the general considered dynamic quenching constant (DQM), 1.0 × 10 10 M −1 ·s −1 . Thus, the static quenching mechanism (SQM), referring to the reactions between the NFCDs and Fe 3+ or AA, might be responsible for the quenching phenomenon caused by Fe 3+ and AA [ 63 , 64 ].…”
Section: Resultsmentioning
confidence: 99%