2015
DOI: 10.1039/c4ra16456c
|View full text |Cite
|
Sign up to set email alerts
|

Carbon dots based turn-on fluorescent probes for oxytetracycline hydrochloride sensing

Abstract: A well-designed turn-on sensor has been constructed and used for the assay of oxytetracycline hydrochloride in real milk samples.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 53 publications
(24 citation statements)
references
References 34 publications
(31 reference statements)
0
24
0
Order By: Relevance
“…Besides, it can be used to establish the sensors to detect metal ions (including Cu(II), Hg(II), Cr(VI), etc. ), dopamine, Cysteine, antibiotics (including tetracycline, oxytetracycline) and so on. Up to now, red, green and blue luminescent CDs have been synthesized using the solvothermal method, where o‐phenylenediamine, m‐phenylenediamine and p‐phenylenediamine are taken as the source of carbon …”
Section: Introductionmentioning
confidence: 86%
“…Besides, it can be used to establish the sensors to detect metal ions (including Cu(II), Hg(II), Cr(VI), etc. ), dopamine, Cysteine, antibiotics (including tetracycline, oxytetracycline) and so on. Up to now, red, green and blue luminescent CDs have been synthesized using the solvothermal method, where o‐phenylenediamine, m‐phenylenediamine and p‐phenylenediamine are taken as the source of carbon …”
Section: Introductionmentioning
confidence: 86%
“…In Israel, fish food in fish ponds is usually supplemented with one of the following antimicrobial compounds: oxytetracycline hydrochloride, sulfadiazine trimethoprim, and florfenicol. When transferring juvenile fish (weighing up to 100 g) between pools, the water is supplemented with oxytetracycline hydrochloride that is an analog of tetracycline (doxycycline) and is also used in humans ( An et al, 2015 ). Indeed, the MIC 90 of doxycycline in the fish isolates was the highest compared to the isolates from the other environmental reservoirs tested in the current study ( Table 1 ).…”
Section: Discussionmentioning
confidence: 99%
“…Table 1 shows the comparison of aptamer-AgNCs with other biosensors with regard to the biosensor performance for the detection of OTC. Limits of detection (LOD) and linear dynamic range of the biosensors were obtained from the literature (25)(26)(27)(28)(29)(30). The linear range of aptamer-AgNCs was 1-100 nM.…”
Section: Selectivitymentioning
confidence: 99%