2019
DOI: 10.1007/s00604-019-3227-x
|View full text |Cite
|
Sign up to set email alerts
|

Carbon-dot wrapped ZnO nanoparticle-based photoelectrochemical sensor for selective monitoring of H2O2 released from cancer cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 39 publications
(13 citation statements)
references
References 35 publications
0
13
0
Order By: Relevance
“…The LOD was measured using a previously reported method (eq S1). 42 The limit of quantification (LOQ) was also calculated (eqs S2), and observed to be 0.51 and 0.0123 μM, respectively for UA and Xn at the NC@HC electrode. Similarly, the linear range and sensitivity were found to be 50−1050 and 05−90 μM and 1.47 and 14.84 μA/μM, respectively for both UA and Xn.…”
Section: Controlled Shape Patterns Of Synthesizedmentioning
confidence: 99%
“…The LOD was measured using a previously reported method (eq S1). 42 The limit of quantification (LOQ) was also calculated (eqs S2), and observed to be 0.51 and 0.0123 μM, respectively for UA and Xn at the NC@HC electrode. Similarly, the linear range and sensitivity were found to be 50−1050 and 05−90 μM and 1.47 and 14.84 μA/μM, respectively for both UA and Xn.…”
Section: Controlled Shape Patterns Of Synthesizedmentioning
confidence: 99%
“…It shows that our LOD is lower than the ones obtained on BiVO 4 , Si, CuO and CdS‐based photoelectrodes. In addition, our linear range, which spans 2 orders of magnitudes in concentration, is large and greater than the ones reported for TiO 2 , WO 3 , ZnO and Cu 2 O‐based photoelectrodes. It is also interesting to note that systems based on the TiO 2 /CdS heterojunction exhibit a lower LOD and a wide linear range, however, these systems may have disadvantages from an environmental point of view.…”
Section: Figurementioning
confidence: 56%
“…So far, PEC sensing has been mainly employed for the detection of biological macromolecules, in immuno‐ or apta‐ assays and has also been explored for the detection of small organic molecules such as antioxidants or glucose . While H 2 O 2 is a widely‐employed hole scavenger in the field of energy‐related photoelectrochemical research (typically used to probe the upper performance of water‐splitting photoanodes), the PEC sensing of H 2 O 2 has been only reported on TiO 2 , WO 3 , ZnO, BiVO 4 , and Si‐based photoanodes and on Cu 2 O, CuO, CdS, and CuInS 2 ‐based photocathodes.…”
Section: Figurementioning
confidence: 99%
“…Besides, monitoring the critical biomarkers in the human body represented an essential basis for health assessment, pharmaceutical guidance, surgical intervention protocols, and postsurgical monitoring (Khan et al, 2019 ; Li et al, 2020 ; Patella et al, 2021 ). Nowadays, there is a high interest in developing efficient strategies to diagnose cancer and fight against it.…”
Section: Nanopatterned Surface To Detect Cellular State and Chemicals Based On Electrochemical Techniquesmentioning
confidence: 99%