2005
DOI: 10.1016/j.ijrefrig.2005.05.019
|View full text |Cite
|
Sign up to set email alerts
|

Carbon dioxide as refrigerant for tap water heat pumps: A comparison with the traditional solution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
55
0
1

Year Published

2008
2008
2021
2021

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 110 publications
(58 citation statements)
references
References 6 publications
2
55
0
1
Order By: Relevance
“…Some studies have been conducted for the performance analysis on water heating systems (Cecchinato et al, 2005;Stene, 2005;Minetto, 2011). However, few studies have been conducted in consideration of daily changes in the aforementioned conditions.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Some studies have been conducted for the performance analysis on water heating systems (Cecchinato et al, 2005;Stene, 2005;Minetto, 2011). However, few studies have been conducted in consideration of daily changes in the aforementioned conditions.…”
Section: Introductionmentioning
confidence: 99%
“…As a result, the system performance is affected by the operational history on past several days, and changes complexly with days. Therefore, in order to attain the maximum system performance, it is necessary to estimate the daily changes in system performance values accurately in relation to those in the ambient conditions, hot water demand, and operating conditions, and determine the operating conditions optimally based on them.Some studies have been conducted for the performance analysis on water heating systems (Cecchinato et al, 2005;Stene, 2005;Minetto, 2011). However, few studies have been conducted in consideration of daily changes in the aforementioned conditions.…”
mentioning
confidence: 99%
“…More directly, others researchers have reported COP improvement with a certain subcooling, although in some cases, the degree of subcooling is not indicated (Cecchinato et al, 2005, Hjerkinn, 2007, Redon et al, 2014. In addition, in a more recent study, Pottker and Hrnjak (2015) theoretically studied the effect of subcooling in an air conditioning system for different refrigerants, they pointed out the existence of an optimal subcooling that maximizes COP for their equipment.…”
Section: Natural Refrigerants For the Shw Application 13mentioning
confidence: 99%
“…This effort has been materialized in projects such as ECO-CUTE in Japan (ECO-CUTE project). Works like (Cecchinato et al, 2005;Nekså et al, 1998;Nekså, 2002;Rieberer et al, 1997) has shown high efficiency of these cycles at water temperature lifts even higher than 50K. Stene (2004) discussed the existence of the gas cooler pinch point and the effect of the rejection pressure control for CO2 heat pump water heaters.…”
Section: The Transcritical Co2 Cyclementioning
confidence: 99%
See 1 more Smart Citation