2020
DOI: 10.1016/j.sab.2020.105839
|View full text |Cite
|
Sign up to set email alerts
|

Carbon detection in solid and liquid steel samples using ultraviolet long-short double pulse laser-induced breakdown spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 25 publications
(14 citation statements)
references
References 37 publications
0
13
0
1
Order By: Relevance
“…During the LS-DP-LIBS processes, the plasma was induced by short pulse, but the generation and development of plasma were affected by long pulse. [30][31][32][33][34] When the plasma was generated by LS-DP-LIBS in this study, the ablated matter was strongly confined inside the cavitation bubble induced by the long pulse to generate the plasma, which can be detected to record the distinguishable emission signal. The plasma pictures of SP-LIBS and LS-DP-LIBS are also presented in Fig.…”
Section: Comparison Of Sp-libs and Ls-dp-libsmentioning
confidence: 86%
See 3 more Smart Citations
“…During the LS-DP-LIBS processes, the plasma was induced by short pulse, but the generation and development of plasma were affected by long pulse. [30][31][32][33][34] When the plasma was generated by LS-DP-LIBS in this study, the ablated matter was strongly confined inside the cavitation bubble induced by the long pulse to generate the plasma, which can be detected to record the distinguishable emission signal. The plasma pictures of SP-LIBS and LS-DP-LIBS are also presented in Fig.…”
Section: Comparison Of Sp-libs and Ls-dp-libsmentioning
confidence: 86%
“…LS-DP-LIBS method demonstrated the signal enhancement and analytical performance improvement for solid steel samples in the atmosphere under various conditions. [30][31][32][33] The measurement features of carbon detection in liquid steel samples using LS-DP-LIBS were also discussed. 33 The superior detection ability for underwater measurement was verified by the measurement of the Al sample and copper sample under water.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The long and short double-pulse LIBS method was proposed by our group and it has been named as LS-DP-LIBS [28,29]. In previous studies [30,31], LS-DP-LIBS has been compared with SP-LIBS based on the measurement results in an air atmosphere. Those studies have demonstrated that the plasma is enhanced and stabilized by LS-DP-LIBS.…”
Section: Introductionmentioning