2007
DOI: 10.1007/s00330-007-0718-7
|View full text |Cite
|
Sign up to set email alerts
|

Capsule enteroscopy and radiology of the small intestine

Abstract: Capsule Enteroscopy and Radiology of the Small Intestine 2 ABSTRACT In a very few years, the video capsule for small bowel enteroscopy has gained widespread clinical acceptance. It is readily ingested, disposable, and allows for a complete, low-invasive endoscopic examination of the entire mucosa of the small bowel. It is a patient-friendly method and a first line procedure in the difficult evaluation of obscure gastrointestinal bleeding. It has the highest proven figure of diagnostic sensitivity for detecting… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
20
0
1

Year Published

2008
2008
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(21 citation statements)
references
References 72 publications
0
20
0
1
Order By: Relevance
“…MRI can be performed using two different approaches: MR enteroclysis or MR enterography [2][3][4][5][6][7][8][9].…”
Section: Technical Consideration and Methodologymentioning
confidence: 99%
See 2 more Smart Citations
“…MRI can be performed using two different approaches: MR enteroclysis or MR enterography [2][3][4][5][6][7][8][9].…”
Section: Technical Consideration and Methodologymentioning
confidence: 99%
“…Bowel wall thickness .3 mm must be considered abnormal [2][3][4][5][6][7][8][9][10][11][12]. MR is able to assess the morphology of the lesion and the endoluminal, mural and extramural abnormalities ( Figure 1); these findings are relevant for the differential diagnosis of small-bowel neoplasms.…”
Section: Image Interpretationmentioning
confidence: 99%
See 1 more Smart Citation
“…Current clinical guidelines recommend the use of radiological studies prior to use of WCE especially in high risk patients 1 . Digital subtraction angiography (DSA) for diagnostic purposes has in the majority of indications been replaced by CT angiography (CTA) while DSA is reserved for guidance of interventional procedures.…”
Section: Markova K Kluchova R Zboril M Mashlan M Hermanmentioning
confidence: 99%
“…1). Duration of the examination, discomfort due to intubation and infusion of large volumes of contrast and distension materials lead to the low acceptance of this method 1 . CE has been shown to be highly accurate, with a sensitivity of 93.1% and a specificity of 96.9% (ref .…”
Section: Conventional Enteroclysis (Ce)mentioning
confidence: 99%