1997
DOI: 10.1136/emj.14.4.222
|View full text |Cite
|
Sign up to set email alerts
|

Capnography for monitoring non-intubated spontaneously breathing patients in an emergency room setting.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
15
0

Year Published

2003
2003
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(18 citation statements)
references
References 3 publications
0
15
0
Order By: Relevance
“…Respiratory rate is out of step with the other vital signs, which are measured electronically. There is a long list of proposed alternatives: capnography by mask, nasal prongs, or mouthpiece [30][31][32] ; pneumotachography (direct flow measurement) by mask or mouthpiece 33,34 ; acoustic monitoring by nasal microphones 30,35 ; nasal thermistors (temperature) 18,34,36 ; fiberoptic nasal sensors that gauge condensation during exhalation 30,37,38 ; inductive plethysmography, which measures chest wall and abdominal movement by bands encircling the trunk (extensometry) 26,33 ; single-compartment and multicompartment air mattresses that measure and compare chest and abdominal volumes [39][40][41] ; mask-mounted pyroelectric polymer strips, which detect temperature variations 32,42 ; transdermal fiberoptic photoplethysmography 30,43,44 ; and transthoracic impedance plethysmography. 13,18,26,30,32,37,[45][46][47] All of the above-mentioned modalities have been reported to correlate well with ''criterion standard'' clinical measurement of respiratory rate.…”
Section: Discussionmentioning
confidence: 99%
“…Respiratory rate is out of step with the other vital signs, which are measured electronically. There is a long list of proposed alternatives: capnography by mask, nasal prongs, or mouthpiece [30][31][32] ; pneumotachography (direct flow measurement) by mask or mouthpiece 33,34 ; acoustic monitoring by nasal microphones 30,35 ; nasal thermistors (temperature) 18,34,36 ; fiberoptic nasal sensors that gauge condensation during exhalation 30,37,38 ; inductive plethysmography, which measures chest wall and abdominal movement by bands encircling the trunk (extensometry) 26,33 ; single-compartment and multicompartment air mattresses that measure and compare chest and abdominal volumes [39][40][41] ; mask-mounted pyroelectric polymer strips, which detect temperature variations 32,42 ; transdermal fiberoptic photoplethysmography 30,43,44 ; and transthoracic impedance plethysmography. 13,18,26,30,32,37,[45][46][47] All of the above-mentioned modalities have been reported to correlate well with ''criterion standard'' clinical measurement of respiratory rate.…”
Section: Discussionmentioning
confidence: 99%
“…Later studies largely focused on isolated evaluation of various numerical parameters and indices describing capnogram shape [5], [6].…”
Section: Introductionmentioning
confidence: 99%
“…Whereas gross changes are visible to the naked eye, for example, "shark fin" appearance, more subtle changes require measurement of the slopes and angles. Because this is still a new concept, in all studies to date, this has been done manually (4,10,11). We have taken a slightly different approach.…”
Section: End-tidal Capnographymentioning
confidence: 99%