Capillary zone electrophoresis with electroosmotic flow controlled by external radial electric field

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0
3

Year Published

2000
2000
2017
2017

Publication Types

Select...
6
2

Relationship

5
3

Authors

Journals

citations
Cited by 47 publications
(21 citation statements)
references
References 18 publications
0
18
0
3
Order By: Relevance
“…The CE measurements were performed with a home-made CE apparatus equipped with a UV photometric detector monitoring absorbance at 206 nm [31] using an internally uncoated fused silica capillary with outer polyimide coating (Polymicro Technologies, Phoenix, AR, USA) of 320/210 mm (total/effective) lengths and 50 m × 375 m (I.D. × O.D.…”
Section: Instrumentation and Experimental Conditionsmentioning
confidence: 99%
“…The CE measurements were performed with a home-made CE apparatus equipped with a UV photometric detector monitoring absorbance at 206 nm [31] using an internally uncoated fused silica capillary with outer polyimide coating (Polymicro Technologies, Phoenix, AR, USA) of 320/210 mm (total/effective) lengths and 50 m × 375 m (I.D. × O.D.…”
Section: Instrumentation and Experimental Conditionsmentioning
confidence: 99%
“…The majority of the reported work has been on characterising the ability to modify the EOF, rather than investigating the benefits of EOF control for the improvement of separation. Culbertson et al and Kašička et al show how the resolution of CE systems can be improved by the control of EOF for capillary based systems [5]. The extension of this to planar systems has received less attention.…”
Section: Controlling the Eof (And Zeta-potential)mentioning
confidence: 99%
“…For the ACE experiments, an adapted home-made CE apparatus [26] equipped with a UV photometric detector monitoring absorbance at 206 nm was used. The ACE separations were performed in the internally uncoated fused silica capillary with an outer polyimide coating, a total/effective length of 306/200 mm, an id/od of 50/375 m. The separations were carried out at ambient temperature, 23-26 • C. A Clarity chromatography and electrophoresis station (DataApex, Prague, CR) was used for data acquisition and evaluation, and the Origin 6.1 program (OriginLab Corp., Northampton, MA, USA) was employed for the non-linear regression analysis.…”
Section: Apparatusmentioning
confidence: 99%