2003
DOI: 10.1016/s0021-9673(02)01737-5
|View full text |Cite
|
Sign up to set email alerts
|

Capillary zone electrophoresis of soil humic acid fractions obtained by coupling size-exclusion chromatography and polyacrylamide gel electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2004
2004
2017
2017

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(6 citation statements)
references
References 24 publications
0
6
0
Order By: Relevance
“…At present, various techniques such as chromatographic techniques based on molecular size (e.g., size exclusion chromatography and gel permeation chromatography), ultrafiltration, reversed-phase highperformance liquid chromatography (RP-HPLC), capillary electrophoresis and flow field flow fractionation have been used to separate and characterize HAs [15][16][17]. Additionally, the structure properties such as polarity and aromaticity of the obtained HAs fractions are diverse, and thus their photoinductive activities would be different from each other.…”
Section: Introductionmentioning
confidence: 99%
“…At present, various techniques such as chromatographic techniques based on molecular size (e.g., size exclusion chromatography and gel permeation chromatography), ultrafiltration, reversed-phase highperformance liquid chromatography (RP-HPLC), capillary electrophoresis and flow field flow fractionation have been used to separate and characterize HAs [15][16][17]. Additionally, the structure properties such as polarity and aromaticity of the obtained HAs fractions are diverse, and thus their photoinductive activities would be different from each other.…”
Section: Introductionmentioning
confidence: 99%
“…[8]. A difficult problem is also the sorption of HM onto uncoated silica capillaries, and for that reason relatively high sample concentrations or long injection times are usually needed.…”
Section: Introductionmentioning
confidence: 99%
“…The pattern of humic substances mainly depends on sample structure, buffer composition and other experimental conditions. In the case of the fused-silica capillary, humic acid samples afford characteristic regions in the electropherogram: a spike (low molecular compounds) and a wide ''humic hump'' (sometimes with poorly defined shoulders) from heterogeneous matter with poorly defined structure [31][32][33]. However, analysis of humic substances in the bare fused-silica capillary is complicated due to the adsorption of the sample on the capillary wall.…”
Section: Humic Acidsmentioning
confidence: 99%