4th Thermophysics and Heat Transfer Conference 1986
DOI: 10.2514/6.1986-1249
|View full text |Cite
|
Sign up to set email alerts
|

Capillary pumped loop GAS and Hitchhiker flight experiments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

1989
1989
2014
2014

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 43 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…This methodology is the most appropriate technique for analyzing the CPL system. The third approach is related to an overall system simulation using existing semi-empirical correlations under 1 g conditions to calculate the pressure drop and heat transfer coefficients in different parts of the CPL (Kroliczek et al, 1984;Ku et al, 1986a;1986b;1987a;1987b;Chalmers et al, 1988;Ku et al, 1988;Benner et al, 1989;Schweickart and Buchko, 1991;Ku, 1993). Some analytical studies concerning the complex transient phenomena of startup have been conducted (Cullimore, 1991).…”
Section: Capillary Pumped Loop Heat Pipesmentioning
confidence: 99%
“…This methodology is the most appropriate technique for analyzing the CPL system. The third approach is related to an overall system simulation using existing semi-empirical correlations under 1 g conditions to calculate the pressure drop and heat transfer coefficients in different parts of the CPL (Kroliczek et al, 1984;Ku et al, 1986a;1986b;1987a;1987b;Chalmers et al, 1988;Ku et al, 1988;Benner et al, 1989;Schweickart and Buchko, 1991;Ku, 1993). Some analytical studies concerning the complex transient phenomena of startup have been conducted (Cullimore, 1991).…”
Section: Capillary Pumped Loop Heat Pipesmentioning
confidence: 99%
“…The standard deviation S was obtained from this large sample. Based on the bias and random errors, a 95% con dence level uncertainty interval was estab- 2 , where t 0.95 is the student distribution coef cient 19,20 ]. A value of 4 ± C was added to the maximum uncertainty limit to account for the already-mentioned conceptual error.…”
Section: Experimental Studymentioning
confidence: 99%
“…One of the recommendations at the review (made by Mr. Brent Cullimore) was to replace the traditional CPL with a loop that utilizes only a single starter pump [8]. A heat pipe imbedded in the cold plate would be used to provide the required isothermalization of the plate and carry heat to the starter pump.…”
Section: Capl 2 Flight Verificationmentioning
confidence: 99%