2008
DOI: 10.1111/j.1745-4557.2007.00162.x
|View full text |Cite
|
Sign up to set email alerts
|

Capillary Extrusion Viscometer for the Viscosity Measurement of Fish Protein Paste

Abstract: To overcome various limitations of conventional viscometers in measuring salted or unsalted surimi paste, a capillary extrusion viscometer was developed. The viscosity of surimi paste was measured as a function of moisture content (MC) (75–80%), salt content (2–4%) and liquid egg white (LEW) content (2–4%). As moisture, salt and LEW contents increased, viscosity gradually decreased. The viscosity values, as affected by MCs, showed a highly negative relationship with fracture properties of surimi gel, especiall… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
4
0

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 11 publications
1
4
0
Order By: Relevance
“…With increased moisture content from 80% to 84%, apparent viscosity decreased. Similar trends were observed in the apparent viscosity of Alaska pollock, which proportionally decreased as moisture content increased from 76% to 86% (Kim and Park 2005). The effect of salt concentration, thawing conditions, and chopping temperature on the density of surimi paste is described in Figure 6.…”
Section: Resultssupporting
confidence: 70%
See 3 more Smart Citations
“…With increased moisture content from 80% to 84%, apparent viscosity decreased. Similar trends were observed in the apparent viscosity of Alaska pollock, which proportionally decreased as moisture content increased from 76% to 86% (Kim and Park 2005). The effect of salt concentration, thawing conditions, and chopping temperature on the density of surimi paste is described in Figure 6.…”
Section: Resultssupporting
confidence: 70%
“…Apparent viscosity of surimi paste was then determined by the slope of shear stress compared with shear rate. Possible slip at the tube wall was thought by Kim and Park (2005) in our first experiments. Preliminary experiments provided with a higher linearity between pressure (force value) and crosshead speeds.…”
Section: Methodsmentioning
confidence: 73%
See 2 more Smart Citations
“…Viscosity measurement was performed according to the method developed by Kim and Park (2005) using a Texture Analyzer (TA‐XT plus; Texture Technologies Corp.) fitted with a capillary fixture kit (TA‐525) having an extrusion tube 30 mm long and a nozzle diameter of 6 mm. Surimi paste remaining after gel analysis was packed into the cylinder using a sausage stuffer (Sausage Maker).…”
Section: Methodsmentioning
confidence: 99%