2004
DOI: 10.1016/j.aca.2004.07.039
|View full text |Cite
|
Sign up to set email alerts
|

Capillary electrophoresis of neurotransmitters with amperometric detection at melanin-type polymer-modified carbon electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
21
0
3

Year Published

2005
2005
2010
2010

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 63 publications
(24 citation statements)
references
References 24 publications
0
21
0
3
Order By: Relevance
“…At the modified electrode, the resolution (R), which was calculated following a previously described equation [31], was found to be much better than that of the bare one. The R value between the DA and the NE at the modified electrode was found to be 2.2, whereas at the bare one, it was [17,18,27]. The relative flat baseline and the low noise levels (peak-to-peak noise levels of 25-30 pA were observed at a modified electrode) at the experimental field strength indicated an effective isolation from the high field strength when the modified electrode was used.…”
Section: Simultaneous Analysis Of Da Ne L-dopamentioning
confidence: 74%
See 1 more Smart Citation
“…At the modified electrode, the resolution (R), which was calculated following a previously described equation [31], was found to be much better than that of the bare one. The R value between the DA and the NE at the modified electrode was found to be 2.2, whereas at the bare one, it was [17,18,27]. The relative flat baseline and the low noise levels (peak-to-peak noise levels of 25-30 pA were observed at a modified electrode) at the experimental field strength indicated an effective isolation from the high field strength when the modified electrode was used.…”
Section: Simultaneous Analysis Of Da Ne L-dopamentioning
confidence: 74%
“…Therefore, the detection and separation of DA has been given tremendous consideration in a biochemical research, especially when there is a need for a sensitive, selective, and fast method for the direct detection of DA. More recently, the determination of neurotransmitters and DNA fragments on a Pt-electrode patterned on a glass chip [23], enzymecatalyzed amperometric oxidation of neurotransmitters on a gold electrode [24], the chiral on-chip separation of neurotransmitters [25], acetylcholine and other neurotransmitters on a sealed electrode into the capillary [26], and neurotransmitters on a polymer modified carbon disk electrode [27] have been reported in the CE-EC electrophoresis system.…”
Section: Introductionmentioning
confidence: 99%
“…Table 1 summarizes the regression equation, correlation coefficient and detection limits [30]. The results demonstrate that the method of alternate running buffers CZE was suitable for the detection of the six analytes, allowing a reproducible and more sensitive quantification of mixtures containing the six analytes.…”
Section: Repeatability Linearity and Detection Limitsmentioning
confidence: 92%
“…The authors also constructed a new EC cell including a Nafion decoupler for CE-ECD. A melanin-type polymermodified glassy-carbon electrode and graphite-carbon electrodes showed sensitivities 3-5 times higher than bare-carbon electrodes and LODs at sub-micromolar levels in neurotransmitter CE-EC [21], because of more efficient electron transfer and excellent permselectivity of the melanin polymers.…”
Section: Electrode Material-besidesmentioning
confidence: 99%