1993
DOI: 10.1021/ac00061a717
|View full text |Cite
|
Sign up to set email alerts
|

Capillary Electrophoresis/Mass Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
98
0

Year Published

1996
1996
2006
2006

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 162 publications
(98 citation statements)
references
References 19 publications
0
98
0
Order By: Relevance
“…Therefore, CE-ESI-MS was employed for the identification of this impurity in cis-ketoconazole because the possible impurities reported in the European Pharmacopoeia [16] have different masses (trans-ketoconazole of exact mass = 530.1487 g/mol; impurity II of exact mass = 528.1331 g/mol; impurity III of exact mass = 720.2481 g/mol and impurity IV of exact mass = 488.1382 g/mol). In order to obtain a limit of detection (LOD) as low as possible, the volatile BGE was used under achiral conditions because the presence of non-volatile components (e.g., cyclodextrins) in the BGE decreases the sensitivity, increases the background noise and can clog the system [18][19][20]. In addition, under achiral conditions, only one peak was observed for the impurity, providing a better sensitivity than that obtained for the two peaks observed under chiral conditions.…”
Section: Detection Of Impurities In Cis-ketoconazole By Ce-uvmentioning
confidence: 99%
“…Therefore, CE-ESI-MS was employed for the identification of this impurity in cis-ketoconazole because the possible impurities reported in the European Pharmacopoeia [16] have different masses (trans-ketoconazole of exact mass = 530.1487 g/mol; impurity II of exact mass = 528.1331 g/mol; impurity III of exact mass = 720.2481 g/mol and impurity IV of exact mass = 488.1382 g/mol). In order to obtain a limit of detection (LOD) as low as possible, the volatile BGE was used under achiral conditions because the presence of non-volatile components (e.g., cyclodextrins) in the BGE decreases the sensitivity, increases the background noise and can clog the system [18][19][20]. In addition, under achiral conditions, only one peak was observed for the impurity, providing a better sensitivity than that obtained for the two peaks observed under chiral conditions.…”
Section: Detection Of Impurities In Cis-ketoconazole By Ce-uvmentioning
confidence: 99%
“…When In this paper we describe the use of capillary electrophoresis (CE) coupled online with ESI-MS (7,8) to probe the synthesized combinatorial libraries for their diversity. CE generates rapid, high-resolution separations based on differences in the electrophoretic mobilities of charged species in an electric field in small-diameter fused-silica capillaries.…”
Section: Poly-functionalized Corementioning
confidence: 99%
“…It is important therefore to understand the real differences and similarities between DNA damage induced by normal oxidative processes versus low doses of ionizing radiation (Henle et al 1996, Dizdaroglu 1992. Recent dramatic advances in analytical methods (Smith et al 1993) 4-9 are now providing significantly more sensitive capabilities for efficiently and quantitatively detecting and characterizing the distinctive and chemically complex damage products from ionizing radiation (Hofstadler et al 1995).…”
Section: Introductionmentioning
confidence: 99%