1998
DOI: 10.1016/s0378-4347(98)00358-2
|View full text |Cite
|
Sign up to set email alerts
|

Capillary electrophoresis–mass spectrometry coupling versus micro-high-performance liquid chromatography–mass spectrometry coupling: a case study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

2
22
0

Year Published

2001
2001
2011
2011

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 32 publications
(24 citation statements)
references
References 27 publications
2
22
0
Order By: Relevance
“…In addition to chromatographic techniques micellar electrokinetic capillary chromatography (MECC) has been used for the confirmation of benzodiazepine compounds in human urine which tested positive by immunoassay screening [31]. It has also been reported that capillary zone electrophoresis (CZE) can provide both different selectivity and greater sensitivity than micro-HPLC for the detection of midazolam and its phase I and II metabolites [32].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…In addition to chromatographic techniques micellar electrokinetic capillary chromatography (MECC) has been used for the confirmation of benzodiazepine compounds in human urine which tested positive by immunoassay screening [31]. It has also been reported that capillary zone electrophoresis (CZE) can provide both different selectivity and greater sensitivity than micro-HPLC for the detection of midazolam and its phase I and II metabolites [32].…”
Section: Introductionmentioning
confidence: 99%
“…Extraction solvents with non-polar, medium polarity, or a mixture of several solvents e.g. n-butyl acetate, toluene, or ethylacetate-hexane (75:25, v/v) have been reported [16][17][18]22,23,27,32]. More selective extraction techniques, e.g.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Some studies have been performed for the comparison of LC-MS and CZE-MS. Lausecker et al [34] found higher absolute sensitivity and different selectivity for the CZE-MS approach compared to microLC-MS for the analysis of a pharmaceutical drug component and its metabolites by applying a sheath-liquid interface for CZE-MS coupling. Peri-Okonny et al reduced analysis time and improved separation for nine basic drugs when applying nonaqueous CZE as opposed to RP-LC [35].…”
Section: Introductionmentioning
confidence: 99%
“…The high electric field strength leads to sputtering of the coating, as well as electrochemical reactions at the interface, mainly electrolysis of water in the positive spray mode. The use of sheathless electrospray emitters is therefore limited by short lifetimes that are typically up to 100 h for standard electrospray and 6 h for nanospray [26,27]. In addition, gas formation caused by solvent oxidation and corrosion of the conductive metal surface can result in mechanical and oxidative stress on the coating.…”
mentioning
confidence: 99%