2022
DOI: 10.1002/jssc.202100952
|View full text |Cite
|
Sign up to set email alerts
|

Capillary electrophoresis applied for the determination of acidity constants and limiting electrophoretic mobilities of ionizable herbicides including glyphosate and its metabolites and for their simultaneous separation

Abstract: Thermodynamic acidity constants and limiting ionic mobilities were determined for polyprotic non‐chromophore analytes using capillary electrophoresis with capacitively coupled contactless conductivity detection. It was not necessary to work with buffers of identical ionic strength as ionic strength effects on effective electrophoretic mobilities were corrected by modeling during data evaluation (software AnglerFish). The mobility data from capillary electrophoresis coupled to conductivity detection were determ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 41 publications
0
9
0
Order By: Relevance
“…As predicted by simulations, see Figure 2A, a BGE with a pH of 10.2 allowed a baseline separation of all analytes by CZE-MS, especially of GLP and its two main metabolites AMPA and SAR (see also discussion in [43]), compare Figure 2B. Due to insufficient ionization efficiency in the ESI process, glyoxylic acid was not detected.…”
Section: Capillary Zone Electrophoresis-msmentioning
confidence: 56%
See 3 more Smart Citations
“…As predicted by simulations, see Figure 2A, a BGE with a pH of 10.2 allowed a baseline separation of all analytes by CZE-MS, especially of GLP and its two main metabolites AMPA and SAR (see also discussion in [43]), compare Figure 2B. Due to insufficient ionization efficiency in the ESI process, glyoxylic acid was not detected.…”
Section: Capillary Zone Electrophoresis-msmentioning
confidence: 56%
“…Due to insufficient ionization efficiency in the ESI process, glyoxylic acid was not detected. Separations at lower pH values were discarded due to insufficient robustness to small pH changes, especially for SAR and glycine, see [43]. The relatively high effective electrophoretic mobility of the slowest target ion SAR also simplified the search for a suitable terminating ion in the first-dimension ITP.…”
Section: Capillary Zone Electrophoresis-msmentioning
confidence: 99%
See 2 more Smart Citations
“…However, the analytical procedures in these works have only been illustrated for the relatively simple matrix of tap water and are difficult to apply to more complex samples. Another study used the software to determine thermodynamic acidity constants and limit ionic mobilities of glyphosate and its metabolites and application in the separation of glyphosate [41]. Regardless, GLUF and MPPA were not the targets of that work.…”
Section: Introductionmentioning
confidence: 99%