2010
DOI: 10.1021/ac101151k
|View full text |Cite
|
Sign up to set email alerts
|

Capillary Electrophoresis

Abstract: in 2007. Meng currently studies aptamers with an emphasis on capillary electrophoresis selection strategies.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
39
0

Year Published

2010
2010
2015
2015

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 60 publications
(40 citation statements)
references
References 230 publications
(250 reference statements)
0
39
0
Order By: Relevance
“…Emerged in the late 1980s and beginnings of the 1990s, monolithic materials have proven to be a good stationary phase in high efficiency separations in high-performance liquid chromatography (HPLC) [1] and capillary electrochromatography (CEC) [2,3]. Numerous monoliths including common polymeric and silicabased monoliths [4] have been developed for the separations of small molecules and high-molecular-weight molecules such as proteins and nucleic acids.…”
Section: Introductionmentioning
confidence: 99%
“…Emerged in the late 1980s and beginnings of the 1990s, monolithic materials have proven to be a good stationary phase in high efficiency separations in high-performance liquid chromatography (HPLC) [1] and capillary electrochromatography (CEC) [2,3]. Numerous monoliths including common polymeric and silicabased monoliths [4] have been developed for the separations of small molecules and high-molecular-weight molecules such as proteins and nucleic acids.…”
Section: Introductionmentioning
confidence: 99%
“…The sensor was operated as a chemiresistor, with the carbon nanotubes forming a random network between interdigitated electrodes, and improved response and recovery times were observed (on the order of 15 min) (Bekyarova et al, 2004). In another work, a carbon nanotube/poly(ethylene-co-vinyl acetate) composite electrode was developed for amperometric detection in Capillary Electrophoresis (Frost et al, 2010). The new electrode also generated improved S/N, decreased fouling, and resulted in better long-term stability (Chen Z. et al, 2009).…”
Section: Cnts-mips Composites: Innovative Materials For Analytical Dementioning
confidence: 99%
“…Contemporary hyphenated CE/ICP-MS and HPLC/ICP-MS techniques for improved characterization of MT isoforms and the determination of stoichiometric formulas of MT metal complexes have also been reported [27][28][29][30]. CE and hyphenated CE techniques, in particular, have been employed given their high separation efficiency, small sample requirements, and reproducibility [31]. Furthermore, CE technology demonstrates high sensitivity, relatively short analysis times, and the potential for parallel operation leading to highthroughput screening capabilities [32][33][34].…”
Section: Model Applications and Experimental Conditionsmentioning
confidence: 99%