2010
DOI: 10.2116/analsci.26.507
|View full text |Cite
|
Sign up to set email alerts
|

Capillary Chromatography Based on Tube Radial Distribution of Aqueous-Organic Mixture Carrier Solvents: Introduction of Double Tubes Having Different Inner Diameters to the System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
16
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 12 publications
(17 citation statements)
references
References 10 publications
1
16
0
Order By: Relevance
“…The tube radial distribution of the carrier solvents in the TRDC system is also supported by other experimental data using polymer particles as analytes [8], phenylboronic acid or iminodiacetic acid-modified fused-silica capillary tubes [9], and double fused-silica capillary tubes with different inner diameters [10], as well as by visual observation that the dyes dissolved in the carrier solution were radially distributed based on their hydrophilic or hydrophobic nature in the micro-channel in a micro-chip or in the capillary tube [11,12]. We also tried to discuss the mechanism of the formation of the inner and outer phases in the tube radial distribution of the solvents [13].…”
supporting
confidence: 71%
See 1 more Smart Citation
“…The tube radial distribution of the carrier solvents in the TRDC system is also supported by other experimental data using polymer particles as analytes [8], phenylboronic acid or iminodiacetic acid-modified fused-silica capillary tubes [9], and double fused-silica capillary tubes with different inner diameters [10], as well as by visual observation that the dyes dissolved in the carrier solution were radially distributed based on their hydrophilic or hydrophobic nature in the micro-channel in a micro-chip or in the capillary tube [11,12]. We also tried to discuss the mechanism of the formation of the inner and outer phases in the tube radial distribution of the solvents [13].…”
supporting
confidence: 71%
“…Related research has been discussed in detail in our previous papers [6,7]. We have developed a capillary chromatography system using an open capillary tube and a water-hydrophilic/hydrophobic organic mixture carrier solution [6][7][8][9][10][11]. This system works …”
Section: Introductionmentioning
confidence: 99%
“…[16][17][18][19][20][21][22][23] Here, instead of acetonitrile (hydrophilic organic solvent), methanol, ethanol, 1,4-dioxane, and 1-propanol were used to prepare the homogeneous ternary mixed carrier solutions that had the specific component ratios of the solvents near the homogeneous-heterogeneous solution boundary region. The component ratios of the solvents in thus prepared carrier solutions were as follows: water-methanol-ethyl acetate (100:20:15 volume ratio), water-ethanol-ethyl acetate (100:20:15 volume ratio), water-1,4-dioxane-ethyl acetate (100:5:10 volume ratio), and water-1-propanol-ethyl acetate (100:10:11 volume ratio).…”
Section: Chromatograms Obtained With the Carrier Solutions Using Varimentioning
confidence: 99%
“…Here, instead of ethyl acetate (hydrophobic organic solvent) in the ternary mixture carrier solution of water-acetonitrile-ethyl acetate as in our previous reports, [16][17][18][19][20][21][22][23] chloroform, hexane, and 1-butanol were used to prepare the homogeneous ternary mixed carrier solutions that had the specific component ratios of the solvents near the homogeneous-heterogeneous solution boundary region. The component ratios of the carrier solutions were as follows: water-acetonitrile-hexane (100:30:1 volume ratio), water-acetonitrile-chloroform (100:30:1 volume ratio), and water-acetonitrile-1-butanol (100:15:20 volume ratio).…”
Section: Chromatograms Obtained With the Carrier Solutions Using Varimentioning
confidence: 99%
See 1 more Smart Citation