2015
DOI: 10.1016/j.renene.2014.10.040
|View full text |Cite
|
Sign up to set email alerts
|

Capacity allocation of a hybrid energy storage system for power system peak shaving at high wind power penetration level

Abstract: a b s t r a c tHigh wind power penetration in power system leads to a significant challenge in balancing power production and consumption due to the intermittence of wind. Introducing energy storage system in wind energy system can help offset the negative effects, and make the wind power controllable. However, the power spectrum density of wind power outputs shows that the fluctuations of wind energy include various components with different frequencies and amplitudes. This implies that the hybrid energy stor… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
44
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 97 publications
(44 citation statements)
references
References 17 publications
(16 reference statements)
0
44
0
Order By: Relevance
“…(4) Use ∆V(λ) and ∆Q(λ) to correct Q(λ) and V(λ), then obtains Q(λ + 1) and V(λ + 1), let λ = λ + 1, go back to Step (2).…”
Section: Reformulation Of Distributional Robust Chance Constraintsmentioning
confidence: 99%
See 1 more Smart Citation
“…(4) Use ∆V(λ) and ∆Q(λ) to correct Q(λ) and V(λ), then obtains Q(λ + 1) and V(λ + 1), let λ = λ + 1, go back to Step (2).…”
Section: Reformulation Of Distributional Robust Chance Constraintsmentioning
confidence: 99%
“…To improve the security of the transmission system, the wind power uncertainty should be considered in the ATC assessment. Therefore, the probability distribution uncertainty of wind power should be considered to carry out robust and economical ATC assessment strategies [2,3].…”
Section: Introductionmentioning
confidence: 99%
“…However, the use of too many solar panels can increase the cost of capital investment and make the power system is unstable due to the uncertainty associated with solar energy [12,13]. In addition, a wide range of studies [14][15][16][17][18][19] found that the use of energy storage systems (ESS) is one of the most effective solutions for quality, reliability and power of SPP and contributes to greater development of efficient energy distribution. Some studies [20,21] showed that the optimal control of ESS in SPP with multiple bus structures that are built using Flexible Alternative Current Transmission Systems (FACTS) and are the Western System Coordinating Council (WSCC) with the uneven impedance distribution will reduce the peak load, the cost of power supply renovation and compensate the negative impact on the environment.…”
Section: Literature Reviewmentioning
confidence: 99%
“…The traditional approach was to set up new power plants with the capability of peak addition, requiring huge capital investment and planning time [6]. A recently proposed approach was to utilize electric energy storages to adjust the peak load [7,8]. With the rapid development of smart grid techniques, demand response (DR) has been gaining acceptance among practitioners as one of the most useful load shedding methods [9,10].…”
Section: Introductionmentioning
confidence: 99%