2020
DOI: 10.1109/tpwrd.2019.2919788
|View full text |Cite
|
Sign up to set email alerts
|

Capacitor Voltage Reduction in Modular Multilevel Converters Under Grid Voltages Unbalances

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
13
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(20 citation statements)
references
References 37 publications
4
13
0
Order By: Relevance
“…Here we elaborate how this proposed method can be easily extended to other unbalanced grid conditions: There are 4 types of unbalanced grid conditions [19], [20]: Two-phase-to-ground fault, three-phase-to-ground fault, single-phase-to-ground fault, and phase-to-phase short circuit fault. In this paper, the vector definition of grid under two-phase-to-ground fault is expressed as equation (3). The vector definitions of other unbalanced grid conditions are shown in Table II (see below).…”
Section: Extension Of the Proposed Methods To Other Unbalanced Gridmentioning
confidence: 99%
See 3 more Smart Citations
“…Here we elaborate how this proposed method can be easily extended to other unbalanced grid conditions: There are 4 types of unbalanced grid conditions [19], [20]: Two-phase-to-ground fault, three-phase-to-ground fault, single-phase-to-ground fault, and phase-to-phase short circuit fault. In this paper, the vector definition of grid under two-phase-to-ground fault is expressed as equation (3). The vector definitions of other unbalanced grid conditions are shown in Table II (see below).…”
Section: Extension Of the Proposed Methods To Other Unbalanced Gridmentioning
confidence: 99%
“…As a result, the capacitor voltage ripples will be unbalanced and will present higher amplitudes [2]. High SM capacitor voltages will cause tripping of the MMC system immediately if they exceed the safe voltage limit [3]. Therefore, the safe operating region of the MMC is limited during such faults [4].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…There are different types of submodule used in MMC such as half-bridge submodule, full-bridge submodule, flying capacitance, neutral point clamp, etc. The half-bridge submodule is efficient as compared to other submodules [Jaiswal, R. et al, 2019;Li, J. et al, 2020].…”
Section: Mathematical Analysis Of Modular Multilevel Converter (Mmc) Fed Bldc Motormentioning
confidence: 99%