2016
DOI: 10.1109/tia.2016.2550527
|View full text |Cite
|
Sign up to set email alerts
|

Capacitor Aging Detection in a DC–DC Converter Output Stage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
15
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(15 citation statements)
references
References 18 publications
0
15
0
Order By: Relevance
“…In the last two decades, many efforts [11][101] have been made to realize the condition monitoring (CM) for capacitors in dc-link applications. Some of them are designed for capacitors dismantled from converters, i.e., offline schemes [11][24].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the last two decades, many efforts [11][101] have been made to realize the condition monitoring (CM) for capacitors in dc-link applications. Some of them are designed for capacitors dismantled from converters, i.e., offline schemes [11][24].…”
Section: Introductionmentioning
confidence: 99%
“…Others are implemented on-site in a real system, i.e., real-online and quasi-online schemes. Here, different types of dc-link applications are considered, such as adjustable speed drive (ASD) systems [25][47], photovoltaic (PV) grid-connected inverters [48][55], power factor correction (PFC) converters [56][61], and dc/dc buck and boost converters [62][101]. Moreover, the implementation methods are various.…”
Section: Introductionmentioning
confidence: 99%
“…(2)(3)(4)(5) Over the last decade, a number of studies have been performed on the failure detection of power capacitors. (6)(7)(8)(9) Sharma et al proposed a fault detection strategy considering single-end-measured fault current data for series capacitors compensating for three-phase transmission lines by using fast Walsh-Hadamard transform (FWHT). (6) Jouybari-Moghaddam et al used an indicating quantity superimposed reactance (SR) method to rapidly locate and identify capacitor element failures in shunt capacitor banks.…”
Section: Introductionmentioning
confidence: 99%
“…(7) Hannonen et al utilized an output voltage transient analysis method to detect capacitor degradation under various operating conditions at the output stage of a step-down dc-dc converter. (8) Carvalho et al presented a virtual instrumentation system developed through acoustic partial discharge signal detection and capacitance monitoring for the assessment of high-voltage-power capacitors. (9) The aforementioned fault types are discussed in this paper.…”
Section: Introductionmentioning
confidence: 99%
“…According to differences in data acquisition, the current research achievement of using ripple to evaluate the health state of AECs can be summarized as the indirect calculation of ripple through simulation software [9][10][11], the offline computing from sampled data [12], AEC parameter calculation based on the mathematical model of a particular topology and some specific measurement value (voltage or current) [13][14][15][16][17][18][19], and direct measurement of ripple through high-cost oscilloscopes, data acquisition cards, or high-speed analog-to-digital converters (ADCs) [20][21][22][23]. Nevertheless, the developed methods are rarely adopted in practical industry applications due to the increased cost, complexity, and other relevant issues [8,24].…”
Section: Introductionmentioning
confidence: 99%