1989
DOI: 10.1111/j.1365-2591.1989.tb00516.x
|View full text |Cite
|
Sign up to set email alerts
|

Capacitance effect of rubber gloves on electric pulp testers

Abstract: Electric pulp testers (EPTs) are widely used to assess tooth pulp vitality. With many unipolar EPTs the electrical circuit is completed through the operator. Since dentists now routinely wear rubber gloves, these might be expected to provide electrical insulation, and therefore to break the circuit. The objective of this investigation was to define the electrical effect of wearing rubber gloves. Two battery-powered unipolar EPTs were examined using a digital storage oscilloscope with an input impedance of 1 M … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1990
1990
2010
2010

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 9 publications
0
3
0
Order By: Relevance
“…Another method is for the cuff of the dentist’s gloves to be rolled down to allow contact of the dentist’s wrist with the EPT handle and with the patient’s face. However, this may potentially compromise protection of the dentist and the patient (Treasure 1989).…”
Section: Circuit Completion Whilst Using Barrier Techniquesmentioning
confidence: 99%
“…Another method is for the cuff of the dentist’s gloves to be rolled down to allow contact of the dentist’s wrist with the EPT handle and with the patient’s face. However, this may potentially compromise protection of the dentist and the patient (Treasure 1989).…”
Section: Circuit Completion Whilst Using Barrier Techniquesmentioning
confidence: 99%
“…Another study found that the use of gloves while performing pulp tests did not alter the readings (Anderson & Pantera 1988). Latex gloves act as a capacitance, altering the electrical output from the EPT (Treasure 1989). Current advice is that gloves can be worn, providing the patient completes the circuit by holding the metal handle of the EPT probe, or a lip clip is used (Kolbinson & Teplitsky 1988, Cailleteau & Ludington 1989, Guerra et al.…”
Section: Clinical Considerationsmentioning
confidence: 99%
“…In a recent study by Booth and Kidd (1988), the use of rubber gloves prevented the functioning of one type of pulp tester, but gave a higher reading with another. Treasure (1989) has shown that the glove acts as a capacitance. The current flow can be altered by turning a dial on the handle of the tester or, in the case of more recent electronic models, the voluge is autotnatically increased with a digital readout to indicate the stimulus.…”
Section: Special Investigationsmentioning
confidence: 99%