2022
DOI: 10.1038/s41598-022-20690-x
|View full text |Cite
|
Sign up to set email alerts
|

Cannulation configuration and recirculation in venovenous extracorporeal membrane oxygenation

Abstract: Venovenous extracorporeal membrane oxygenation is a treatment for acute respiratory distress syndrome. Femoro-atrial cannulation means blood is drained from the inferior vena cava and returned to the superior vena cava; the opposite is termed atrio-femoral. Clinical data comparing these two methods is scarce and conflicting. Using computational fluid dynamics, we aim to compare atrio-femoral and femoro-atrial cannulation to assess the impact on recirculation fraction, under ideal conditions and several clinica… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(12 citation statements)
references
References 25 publications
1
11
0
Order By: Relevance
“…Whilst being zero at 2 and 4 L/min, at 6 L/min increased slightly to 3.0–6.2%. Compared to data from SLCs in atrio-femoral and femoro-atrial configurations, using the same patient-averaged model 10 , DLC at the baseline position was much lower (Fig. 2 A) with the exception of 2 L/min where both cannula strategies have near-zero recirculation.…”
Section: Resultsmentioning
confidence: 81%
See 4 more Smart Citations
“…Whilst being zero at 2 and 4 L/min, at 6 L/min increased slightly to 3.0–6.2%. Compared to data from SLCs in atrio-femoral and femoro-atrial configurations, using the same patient-averaged model 10 , DLC at the baseline position was much lower (Fig. 2 A) with the exception of 2 L/min where both cannula strategies have near-zero recirculation.…”
Section: Resultsmentioning
confidence: 81%
“…Two commonly used DLC designs, the Maquet Avalon Elite® (Getinge, Rastatt, Germany) and MC3 Crescent® (Medtronic International Trading Sàrl, Tolochenaz, Switzerland) were sectioned manually with a blade, measured with vernier calipers, and reconstructed into accurate 3D CAD geometries. Following the same methodology, as previously used by us with SLCs 10 , we positioned 3D reconstructions of each device in the patient-averaged model following venous centrelines, also modelling them as rigid-wall. A 27Fr cannula size was selected for the patient-averaged model mimicking a reasonable clinical choice of cannula size.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations