2009
DOI: 10.1016/j.ahj.2008.08.009
|View full text |Cite
|
Sign up to set email alerts
|

Cancer risk from professional exposure in staff working in cardiac catheterization laboratory: Insights from the National Research Council's Biological Effects of Ionizing Radiation VII Report

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
207
0
6

Year Published

2009
2009
2016
2016

Publication Types

Select...
7
1
1

Relationship

2
7

Authors

Journals

citations
Cited by 298 publications
(214 citation statements)
references
References 43 publications
1
207
0
6
Order By: Relevance
“…Radioprotective caps of 0.3-0.5 mm lead equivalence have been shown to significantly attenuate the radiation dose to the operator's head [43,44]. The prevalence of breast cancer has also been shown to be higher among female interventionists [3,45]. Lead-equivalent garments providing snug fit, full chest coverage (sleeved aprons) or dedicated breast shields are recommended for female operators to protect the breast tissue and axillary region.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Radioprotective caps of 0.3-0.5 mm lead equivalence have been shown to significantly attenuate the radiation dose to the operator's head [43,44]. The prevalence of breast cancer has also been shown to be higher among female interventionists [3,45]. Lead-equivalent garments providing snug fit, full chest coverage (sleeved aprons) or dedicated breast shields are recommended for female operators to protect the breast tissue and axillary region.…”
Section: Discussionmentioning
confidence: 99%
“…Ionizing radiation carries potential health hazards for the patient and staff [1][2][3]. Education and training play an important role in balancing minimization of these risks and prevention of 'radiation phobia' which may affect decisions to provide effective diagnostic and treatment options for the patient or preclude the physicians themselves from pursuing carrier in invasive cardiology [4].…”
Section: Background/introductionmentioning
confidence: 99%
“…34 Concern for damaging effects of radiation from interventional cardiac procedures is typically directed at patients; 35 however, impact on cardiologists is not as often addressed. 36 Eye lens cataracts are common and stochastic effects from radiation are also becoming a concern for interventional cardiologists. Cumulative radiation exposure from a working lifetime has been reportedly high enough to increase the cardiologist risk of cancer to 51% 37,38 from the baseline risk of 25%.…”
Section: Discussionmentioning
confidence: 99%
“…(14)(15)(16) We can indirectly estimate the effective radiation doses for the present study by converting the DAP values in the present study using the recommended conversion factor for cardiac ablation procedures. (17) When this conversion was done, we obtained an estimated effective radiation dose of 3.1 millisieverts (mSv) for patients with AVNRT who underwent ablation using CF.…”
Section: Discussionmentioning
confidence: 99%