1990
DOI: 10.1016/0360-3016(90)90282-o
|View full text |Cite
|
Sign up to set email alerts
|

Can simulation measurements be used to predict the irradiated lung volume in the tangential fields in patients treated for breast cancer?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
35
0
2

Year Published

1994
1994
2012
2012

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 101 publications
(38 citation statements)
references
References 9 publications
1
35
0
2
Order By: Relevance
“…The corresponding lung from an atlas could have been used as a template, provided, the atlas takes into account the factors that influence the volume and hence the area of the different slices of the lung. Registration becomes expensive due to the fact that lung volume varies with respect to several factors [14][15][16] and the lung size and shape differs between slices. Hence, in this work to reconstruct the convex border of the lung with severe pathology, the other lung from the same slice is used.…”
Section: Literature Surveymentioning
confidence: 99%
“…The corresponding lung from an atlas could have been used as a template, provided, the atlas takes into account the factors that influence the volume and hence the area of the different slices of the lung. Registration becomes expensive due to the fact that lung volume varies with respect to several factors [14][15][16] and the lung size and shape differs between slices. Hence, in this work to reconstruct the convex border of the lung with severe pathology, the other lung from the same slice is used.…”
Section: Literature Surveymentioning
confidence: 99%
“…Simu las yon fil min de tan jan si yel ala nın ar ka ke na rı ile ön gö ğüs du va rı ara sın da ki dik me sa fe olan san tral ak ci ğer me sa fe si (CLD) öl çül müştür. 17 Rad yo te ra pi tek ni ği nin ak ci ğer hac mi ne et ki si bü yük oran da CLD'ye bağ lı bu lun muştur. CLD 1.5 cm ol du ğun da tan jan si yel alan da ki ak ci ğer hac mi yak la şık ola rak %6, CLD 2.5 cm iken, ışın lanan akci ğer hac mi yak la şık %16, CLD 3.5 cm ol du ğun da ışın lanan ip si la te ral ak ci ğer hac mi %26 ola rak hesap lan mış tır.…”
Section: Tar Tiş Maunclassified
“…CLD 1.5 cm ol du ğun da tan jan si yel alan da ki ak ci ğer hac mi yak la şık ola rak %6, CLD 2.5 cm iken, ışın lanan akci ğer hac mi yak la şık %16, CLD 3.5 cm ol du ğun da ışın lanan ip si la te ral ak ci ğer hac mi %26 ola rak hesap lan mış tır. 17 Bu me sa fe nin 3 cm'den faz la ol ma sı özel lik le sol me me de önem li de re ce de kalp ve ak ciğer hac mi nin ışın lan ma sı na ne den ol mak ta dır.…”
Section: Tar Tiş Maunclassified
“…0026 mm. A CLD of 1.5 cm predicted that approximately 6% of the ipsilateral lung would be included in the tangential field, a CLD of 2.5 cm, approximately 16%, and a CLD of 3.5 cm, approximately 26% of the ipsilateral lung 18 .…”
Section: Patients Characteristicsmentioning
confidence: 99%