1998
DOI: 10.1002/jmri.1880080303
|View full text |Cite
|
Sign up to set email alerts
|

Can MRCP replace ERCP?

Abstract: Magnetic resonance cholangiopancreatography (MRCP) has replaced direct cholangiography and pancreatography in many instances. Its complete noninvasiveness and flexibility are less onerous for patients. For the use of screening as well as scrutiny, MRCP has played an important role in diagnosing various pathologies in this field. The usefulness of MRCP is not limited to anatomical evaluations; it can also yield physiologic and functional information. From a cost-performance basis, MRCP is undoubtedly superior t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0
2

Year Published

1999
1999
2016
2016

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 53 publications
(20 citation statements)
references
References 60 publications
(20 reference statements)
0
18
0
2
Order By: Relevance
“…The advent of FSE sequences has shortened imaging time significantly. 36 These are rapid acquisition and relaxation enhancement (RARE) techniques. The acquisition of data and the filling of K-space has allowed these sequences to become breath-holding using half-Fourier methods to fill K-space, for example in the half-Fourier single-shot turbo spin echo (HASTE) sequence.…”
Section: Mrcpmentioning
confidence: 99%
“…The advent of FSE sequences has shortened imaging time significantly. 36 These are rapid acquisition and relaxation enhancement (RARE) techniques. The acquisition of data and the filling of K-space has allowed these sequences to become breath-holding using half-Fourier methods to fill K-space, for example in the half-Fourier single-shot turbo spin echo (HASTE) sequence.…”
Section: Mrcpmentioning
confidence: 99%
“…Several studies comparing CT with MRCP have shown that the latter is safe and as good as, if not better than, CT for both diagnosing and grading severe acute pancreatitis 63 -66 . The benefits of MRCP include images of superior resolution without the use of ionizing radiation or large volumes of iodinated contrast media 67,68 . However, a number of problems may be encountered, mainly owing to prolonged scan times, including breathing artefacts, bowel peristalsis and vascular motion artefacts, and gastrointestinal air and metallic clips creating susceptibility artefacts, all of which serve to degrade image quality 69 .…”
Section: Magnetic Resonance Cholangiopancreatographymentioning
confidence: 99%
“…However, a number of problems may be encountered, mainly owing to prolonged scan times, including breathing artefacts, bowel peristalsis and vascular motion artefacts, and gastrointestinal air and metallic clips creating susceptibility artefacts, all of which serve to degrade image quality 69 . It should be appreciated, however, that MRCP is still evolving and the results are expected to improve with increasing experience and faster equipment 67 .…”
Section: Magnetic Resonance Cholangiopancreatographymentioning
confidence: 99%
“…Biliary strictures are also not visualised directly on CT. ERCP and PTC are invasive imaging modalities. 3 MRCP since its introduction by Wallner et al in 1991 has experienced remarkable growth in the diagnosis of biliary diseases. It has now assumed the position of modality of choice in the evaluation of biliary tree and pancreatic duct.…”
Section: How To Cite This Articlementioning
confidence: 99%