2021
DOI: 10.1590/1807-3107bor-2021.vol35.0003
|View full text |Cite
|
Sign up to set email alerts
|

Can kinematics, file diameter, and PUI influence the intracanal decontamination and apical bacterial extrusion?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(14 citation statements)
references
References 35 publications
(62 reference statements)
0
5
0
Order By: Relevance
“…Absorbent paper point #20 (Dentsply Maillefer, Ballaigues, Switzerland) was inserted into the canals for 1 min each and then transferred to microtubes containing 1 mL of BHI broth according to previous studies. 10,26 The microtubes were vortexed for 10 s, and 100 μL of the content was transferred by dilution to other microtubes with 900 µL of BHI until a concentration of 10 -3 was reached. Next, 100-μL aliquots of the dilutions were plated on Petri dishes with BHI agar, which were stored in a bacteriological incubator at 37°C for 48 h for subsequent CFU/ mL counts.…”
Section: Microbiological Samplesmentioning
confidence: 99%
See 1 more Smart Citation
“…Absorbent paper point #20 (Dentsply Maillefer, Ballaigues, Switzerland) was inserted into the canals for 1 min each and then transferred to microtubes containing 1 mL of BHI broth according to previous studies. 10,26 The microtubes were vortexed for 10 s, and 100 μL of the content was transferred by dilution to other microtubes with 900 µL of BHI until a concentration of 10 -3 was reached. Next, 100-μL aliquots of the dilutions were plated on Petri dishes with BHI agar, which were stored in a bacteriological incubator at 37°C for 48 h for subsequent CFU/ mL counts.…”
Section: Microbiological Samplesmentioning
confidence: 99%
“…The apical third of the tooth was not used due to the reduced number of dentinal tubules and variable anatomy, as previously observed. 21,24,25,26 In total, 80 images were obtained for each group, as well as 48 images for the positive controls (C + ) and 16 for the negative controls (C -). The images were obtained at a 1-μm step size deep and a resolution of 1024x1024 pixels.…”
Section: Preparation For Confocal Laser Scanning Microscopy (Clsm) Analysismentioning
confidence: 99%
“…The tip diameter of PTU F5 is 0.50 mm, and its taper in the first three millimeters is 0.05 mm. According to a previous study, 20 an increase in file diameter did not reveal a significant difference in AED; however, pressure and friction provided by the file could also affect the amount of AED.…”
Section: Discussionmentioning
confidence: 68%
“…During extrusion experiments, primarily single-rooted premolar teeth were used. 8 , 9 , 11 , 13 , 19 , 20 The mean minimum diameter of the apical foramina of maxillary palatal roots was greater than of mandibular premolar roots, 30 and an increase in foramen diameter increases the risk of extrusion. 31 In addition, maxillary molars have a complex root canal anatomy 32 that reduces the success rate of initial treatment, and their roots may be located in the maxillary sinus, which increases the extrusion potential of filling materials, irrigants, and tissue debris.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation