2001
DOI: 10.1016/s0921-4534(01)00754-7
|View full text |Cite
|
Sign up to set email alerts
|

Calibration of the open-flat coil-based tunnel diode oscillator technique (OFC magnetometer) for quantitative extraction of physical characteristics of superconductive state

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
23
0

Year Published

2002
2002
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(23 citation statements)
references
References 6 publications
0
23
0
Order By: Relevance
“…Besides, due to flat shape, even a little shift of the position of a normal-conducting plate, placed near the coil, may www.intechopen.com lead to strong distortion of the field distribution around the coil. These features, and the stability of TD-oscillators (F stability 1-10Hz, F/F10  7 -10  6  depending on the model & temperature  see [2,[11][12]) enabled us to reach 6 orders relative resolution in SFCO technique [3][4], permitting to effectively use it in a basic research [5][6][7][8], as well as in some modern technical applications [9][10]. In the last case, frequency of the oscillator is mainly used as a testing parameter, and the measuring effect is determined by a distortion of the MHz-range testing field configuration near the coil face by the vibrating copper plate, leading to the magnetic inductance changes of the coil, with a resolution  1-10pH (depending on operation temperature of a technique), resulting in the changes of test oscillator frequency.…”
Section: Flat-coil Based Measurement Technology: Its Advantagesmentioning
confidence: 99%
See 4 more Smart Citations
“…Besides, due to flat shape, even a little shift of the position of a normal-conducting plate, placed near the coil, may www.intechopen.com lead to strong distortion of the field distribution around the coil. These features, and the stability of TD-oscillators (F stability 1-10Hz, F/F10  7 -10  6  depending on the model & temperature  see [2,[11][12]) enabled us to reach 6 orders relative resolution in SFCO technique [3][4], permitting to effectively use it in a basic research [5][6][7][8], as well as in some modern technical applications [9][10]. In the last case, frequency of the oscillator is mainly used as a testing parameter, and the measuring effect is determined by a distortion of the MHz-range testing field configuration near the coil face by the vibrating copper plate, leading to the magnetic inductance changes of the coil, with a resolution  1-10pH (depending on operation temperature of a technique), resulting in the changes of test oscillator frequency.…”
Section: Flat-coil Based Measurement Technology: Its Advantagesmentioning
confidence: 99%
“…Below, we discuss work-principle, and test data of such a new position sensor, installed in a known Russian SM-3 seismometer (for validation) as an additional pick-up element -showing its advantages compared to traditional techniques. We also discuss potentials of this novel absolute-position sensor, operating down to liquid- 4 He temperatures, and in high magnetic fields -as a real-time measurement element for early detection of earthquakes, incoming tsunamis, tidal motion, and for tracking borders. We discuss also possible design of seismic detectors based on this sensor.…”
Section: Flat Coil-based Absolute-position Sensor For Nano-scale Resomentioning
confidence: 99%
See 3 more Smart Citations