2011
DOI: 10.1049/iet-smt.2009.0124
|View full text |Cite
|
Sign up to set email alerts
|

Calibration of on-line partial discharge measuring system using Rogowski coil in covered-conductor overhead distribution networks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
23
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 51 publications
(23 citation statements)
references
References 10 publications
0
23
0
Order By: Relevance
“…Thanks to its versatility, working principle, reduced dimensions, and ease of installation, in the last decade the Rogowski coil has been implemented in many applications [ 28 ] and has been subject to a variety of different studies to improve its knowledge and operation. For example, it is commonly adopted for the detection of partial discharges (PD) [ 29 , 30 ]. Furthermore, its large bandwidth makes it suitable for different high frequency applications [ 31 , 32 , 33 ].…”
Section: Introductionmentioning
confidence: 99%
“…Thanks to its versatility, working principle, reduced dimensions, and ease of installation, in the last decade the Rogowski coil has been implemented in many applications [ 28 ] and has been subject to a variety of different studies to improve its knowledge and operation. For example, it is commonly adopted for the detection of partial discharges (PD) [ 29 , 30 ]. Furthermore, its large bandwidth makes it suitable for different high frequency applications [ 31 , 32 , 33 ].…”
Section: Introductionmentioning
confidence: 99%
“…Chiampi studies on the development and application of a programmable partial discharge calibrator [1], which describes a programmable partial discharge calibrator. Hashmi GM discussed line partial discharge detection enriching the partial discharge theory [2]. Therefore, the test environment is complexity and it is need the PD map to analysis in detail to avoid wrong judgments.…”
Section: Introductionmentioning
confidence: 99%
“…Added to the circuit directly across sensor coil terminals is a terminating resistor R T , which provides active load for damping the resonant oscillations of the circuit. While its role has not been emphasized [6][7], it is a major component that can define the sensor operating mode. The inductive sensor system output is an active measurement device, represented as a voltmeter in Fig.…”
Section: High-frequency Sensor Characteristics and Connection To mentioning
confidence: 99%
“…This is where the wide-bandwidth air-core inductive sensors provide outstanding performance. Implementing the inductive sensors for partial discharge measurements has been proposed also before [6] [7] with sensors indicated bandwidths of up to several hundreds of MHz [8], although the role of resonance and the measurement system characteristics has generally been neglected. The possible different operating modes of an inductive sensor have also been presented in [9] while criteria for the pulsed phenomena measurements have not been clearly identified in the context.…”
Section: Introductionmentioning
confidence: 99%