Calibration of acoustic emission sensors with laser-generated ultrasonic wave.

Abstract: Laser-generated ultrasonic wave is employed as a standard acoustic emission (AE) source to calibrate sensors. Characteristics of ultrasonic wave concerning its genera tionefficiency and directivity were investigated. By covering a transfer block with water layer, a unipolar planar pulse with 80 ns duration was efficiently generated. The surface excitation was interrogated by an optical interferometer, and subsequently measured by AE sensors. Comparing these outputs, the sensitivity of AE sensors can be determi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
5
0

Year Published

1994
1994
2021
2021

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 5 publications
(1 reference statement)
1
5
0
Order By: Relevance
“…The trend of different RW and NW sensitivities found here is consistent with the behavior observed by Matsuda et al [34,35], using direct laser interferometry, as shown in Figure 2. However, it disagreed with the finding of Sause and Hamstad [23], who found that the receiving sensitivities to four wave types were identical.…”
Section: Rayleigh Wave Calibration Of Ae Sensorssupporting
confidence: 92%
See 3 more Smart Citations
“…The trend of different RW and NW sensitivities found here is consistent with the behavior observed by Matsuda et al [34,35], using direct laser interferometry, as shown in Figure 2. However, it disagreed with the finding of Sause and Hamstad [23], who found that the receiving sensitivities to four wave types were identical.…”
Section: Rayleigh Wave Calibration Of Ae Sensorssupporting
confidence: 92%
“…( a ) Laser interferometric calibration results of Matsuda et al [34,35]. NW (solid curve) and RW (dash curve) receiving sensitivities for AE900M sensor.…”
Section: Figurementioning
confidence: 99%
See 2 more Smart Citations
“…For ultrasonic works in SHM and industrial NDE, low MHz frequencies are typically used, and many applications utilize contact transducers because of practicality and cost. For UT and AE transducers, their calibration utilizes optical interferometry, capacitive sensing and substitution methods [ 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 ]. The transmission sensitivity (displacement or velocity per unit input voltage) can be readily determined by pulse excitation plus laser interferometry, but was not reported for broadband UT transducers until recently [ 21 , 22 ].…”
Section: Introductionmentioning
confidence: 99%