2021
DOI: 10.1364/ao.437391
|View full text |Cite
|
Sign up to set email alerts
|

Calibration of a polarization image sensor and investigation of influencing factors

Abstract: Polarization measurements conducted with a polarization camera using the Sony IMX 250 MZR polarization image sensor are assessed with the super-pixel calibration technique and a simple test setup. We define an error that quantifies the quality of the polarization measurements. Multiple factors influencing the measurement quality of the polarization camera are investigated and discussed. We demonstrate that polarization measurements are generally consistent throughout the sensor if not corrupted by large chief … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
15
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 40 publications
(31 citation statements)
references
References 31 publications
1
15
0
Order By: Relevance
“…Particularly, the lens has been correctly focused at the light source, and the f -number has been set higher than 2.8 for all the experiments. Finally, we have acquired several images with the camera in total darkness and verified that, with a 12-bit pixel count and an exposure time of 1s, the dark current can effectively be neglected as reported in [17].…”
Section: Methodssupporting
confidence: 56%
See 2 more Smart Citations
“…Particularly, the lens has been correctly focused at the light source, and the f -number has been set higher than 2.8 for all the experiments. Finally, we have acquired several images with the camera in total darkness and verified that, with a 12-bit pixel count and an exposure time of 1s, the dark current can effectively be neglected as reported in [17].…”
Section: Methodssupporting
confidence: 56%
“…in a dark room to reduce the influence of the environment. Furthermore, the recommendations given in [17] have been followed. Particularly, the lens has been correctly focused at the light source, and the f -number has been set higher than 2.8 for all the experiments.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The default gain setting was used, and the exposure time was set to ensure a dynamic range of about 70%. The camera was not calibrated, as measurement errors are estimated to remain below 4% for this setting (Lane et al 2022).…”
Section: Methodsmentioning
confidence: 99%
“…It is difficult to fabricate an adjustable attenuation microarray mask with conventional optical coating processes. But the adjustable attenuation rate can be achieved indirectly by micro-polarization array mask [20] . The principle of an imaging system with adjustable dynamic range is shown in Figure 1 [21] .…”
Section: Theory and Methodsmentioning
confidence: 99%