2014
DOI: 10.1088/1748-0221/9/10/p10012
|View full text |Cite
|
Sign up to set email alerts
|

Calibration and performance of the photon sensor response of FACT — the first G-APD Cherenkov telescope

Abstract: The First G-APD Cherenkov Telescope (FACT) is the first in-operation test of the performance of silicon photo detectors in Cherenkov Astronomy. For more than two years it is operated on La Palma, Canary Islands (Spain), for the purpose of long-term monitoring of astrophysical sources. For this, the performance of the photo detectors is crucial and therefore has been studied in great detail. Special care has been taken for their temperature and voltage dependence implementing a correction method to keep their p… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
111
0
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
4
3
2

Relationship

1
8

Authors

Journals

citations
Cited by 104 publications
(112 citation statements)
references
References 18 publications
0
111
0
1
Order By: Relevance
“…These promising properties make them particularly suitable for applications in the ground-based Cherenkov gammaray astronomy. More details concerning the performance of this novel technique are given in [6].…”
Section: Introductionmentioning
confidence: 99%
“…These promising properties make them particularly suitable for applications in the ground-based Cherenkov gammaray astronomy. More details concerning the performance of this novel technique are given in [6].…”
Section: Introductionmentioning
confidence: 99%
“…Geiger-mode avalanche photodiodes), the telescope is ideally suited for long-term monitoring. The stable detector performance provided by the photosensors facilitates the analysis of a long-term data sample [9]. Furthermore, it helps to automate the operation of the instrument [10] which increases the data taking efficiency.…”
Section: Status Of Monitoring At Tev Energiesmentioning
confidence: 99%
“…However coupling several small SiPMs into a large detector is possible and the detector noise hardly ever dominates over NSB. Furthermore progress in the field of SiPM is quick and FACT [22] has already proved that SiPM can be used in IACTs. Advantages of SiPM are their high PDE, no ageing effects (after 3 years of operation none of the SiPMs in FACT has failed or shown any indication of ageing), excellent uniformity and, relevant for MACHETE, the fact that they can be used under the brightest Moonlight.…”
Section: Focal Plane Instrumentation and Readoutmentioning
confidence: 99%