2011
DOI: 10.1364/ao.50.002759
|View full text |Cite
|
Sign up to set email alerts
|

Calculation of the modulation transfer function for object brightness distribution function oriented along any direction in axis-symmetrical optical systems

Abstract: The literature deals with the modulation transfer function (MTF) only for object brightness distribution functions (OBDFs) oriented along the meridional and sagittal directions. This paper addresses computation of the geometrical MTF for an off-axis source point when the OBDF is oriented along any arbitrarily defined direction. This study finds that the MTF is not a monotonic increasing or decreasing function when the direction of the OBDF is changing. Consequently, the extreme MTF values may occur when the OB… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 11 publications
0
7
0
Order By: Relevance
“…24 Second, a simple DOF measurement was used and we did not test whether applying the new contrast calculation methods proposed recently could achieve more accurate results. [25][26][27][28][29] Third, although the DOF of the human eye is also an important factor affecting subjective evaluation of the cytogenetic image qualities, 30,31 it was not tested or discussed. Hence, a more comprehensive investigation is underway from which we hope to acquire better knowledge about the designing trade-off parameters to optimize the automated digital microscopic image scanning systems for cytogenetic image diagnosis and other digital pathology applications in the future.…”
Section: Discussionmentioning
confidence: 99%
“…24 Second, a simple DOF measurement was used and we did not test whether applying the new contrast calculation methods proposed recently could achieve more accurate results. [25][26][27][28][29] Third, although the DOF of the human eye is also an important factor affecting subjective evaluation of the cytogenetic image qualities, 30,31 it was not tested or discussed. Hence, a more comprehensive investigation is underway from which we hope to acquire better knowledge about the designing trade-off parameters to optimize the automated digital microscopic image scanning systems for cytogenetic image diagnosis and other digital pathology applications in the future.…”
Section: Discussionmentioning
confidence: 99%
“…One method is based on fixed characteristic targets including the sine-wave method, spots, slits and edge method [4][5][6]. The other method is based on random targets [7].…”
Section: Introductionmentioning
confidence: 99%
“…They can be determined either from scalar wave theory or from geometrical optics. These two approaches are generally referred to as the diffractive MTF and the geometric MTF respectively [4]. Any MTF quantifies the system's capacity to spatially resolve a sinusoidal intensity pattern with discernible contrast [4,7].…”
Section: Introductionmentioning
confidence: 99%
“…These two approaches are generally referred to as the diffractive MTF and the geometric MTF respectively [4]. Any MTF quantifies the system's capacity to spatially resolve a sinusoidal intensity pattern with discernible contrast [4,7]. Previous studies have proposed several methods for measuring the MTF of optical systems based on detector arrays of charge-coupled devices (CCDs) [8] and most of them differ essentially in the type of target or pattern used as the object pattern [9].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation