2005
DOI: 10.12693/aphyspola.107.784
|View full text |Cite
|
Sign up to set email alerts
|

Calculation of Positron Response from Embedded Nanoparticles

Abstract: Nanoparticles embedded in a matrix can trap positrons under certain conditions. In such cases nanoparticles can be effectively studied by means of positron annihilation because positron annihilation characteristics contain information related to nanoparticles' electronic and atomic structure. Of great importance is to calculate the positron response from such nanoparticles. Then, nanoparticles can, in principle, be identified by comparing the measured and calculated positron annihilation response. For this pur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 19 publications
0
10
0
Order By: Relevance
“…(1), clusters with very small size can trap positrons, but this does not necessarily mean that the positron wavefunction will be totally confined inside the clusters. In Fe-Cu alloy, the estimated minimum diameter is 0.74 nm for Cu clusters to trap positrons, however theoretical calculation indicates that at least a diameter of 1.0 nm is needed to completely confine the positrons, so that the positron annihilation parameter will be close to that of pure Cu [31]. For smaller clusters, the positron wavefunction will be weakly localized.…”
Section: Resultsmentioning
confidence: 97%
“…(1), clusters with very small size can trap positrons, but this does not necessarily mean that the positron wavefunction will be totally confined inside the clusters. In Fe-Cu alloy, the estimated minimum diameter is 0.74 nm for Cu clusters to trap positrons, however theoretical calculation indicates that at least a diameter of 1.0 nm is needed to completely confine the positrons, so that the positron annihilation parameter will be close to that of pure Cu [31]. For smaller clusters, the positron wavefunction will be weakly localized.…”
Section: Resultsmentioning
confidence: 97%
“…Positron annihilation lifetimes (PALs) were calculated by means of the ATSUP program [3,11] based on the atomic superposition method [12,13]. Both FREEVOL and ATSUP codes were updated in order to allow handling nanowires.…”
Section: Computational Analysis Methodsmentioning
confidence: 99%
“…Positron lifetimes (PLs) and high momentum parts (HMPs) of the momentum distribution of annihilation γ-quanta were calculated by means of the ATSUP programme [6,7] based on the atomic superposition method [8,9]. The enhancement factor and correlation part of the positron potential were determined using the parameterisation obtained by Boroński and Nieminen [10].…”
Section: Computational Analysis Methodsmentioning
confidence: 99%
“…In the same way, E Co was used to calculate the PBE for defects C1 and C2 and vacancy clusters in Co. In order to account for the Ag-Co affinity difference, the positron response for AC1 defect was calculated applying a shift (E S ) of the positron potential around Co atomic sites in a sphere with the radius R = 2.75Å [7]. An appropriate E S value was estimated using the formula [14] are the positron affinities of Ag and Co, respectively.…”
Section: Simulation Of Positron Responsementioning
confidence: 99%
See 1 more Smart Citation