2004
DOI: 10.1143/jjap.43.5558
|View full text |Cite
|
Sign up to set email alerts
|

Calculation of Ozone Generation in AC Corona Discharge Reactor

Abstract: The aim of this work is to study the analytical calculation of ozone generation in an ac corona discharge reactor. The corona discharges were generated in a dry air-fed wire-duct reactor stressed by an ac voltage at atmospheric pressure and room temperature. The current–voltage characteristics of the ac corona discharges relative to ozone generation in the reactor were measured under different discharge conditions. Subsequently, an empirical equation was derived for the calculation of the ozone concentration g… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 8 publications
(11 citation statements)
references
References 10 publications
0
11
0
Order By: Relevance
“…Subsequently, most of the ozone molecules generated inside the reactor are immediately swept by the flowing air molecules outside the reactor without destruction. 9,11 This explains why the ozone destruction coefficient K d of Eq. (13) decreases with the increase of the air flow rate Q through the reactor.…”
Section: Discussionmentioning
confidence: 97%
See 2 more Smart Citations
“…Subsequently, most of the ozone molecules generated inside the reactor are immediately swept by the flowing air molecules outside the reactor without destruction. 9,11 This explains why the ozone destruction coefficient K d of Eq. (13) decreases with the increase of the air flow rate Q through the reactor.…”
Section: Discussionmentioning
confidence: 97%
“…On the other hand, there are several mechanisms for destruction of the ozone generated by either corona or silent discharges in dry air-fed reactors. [6][7][8][9] Subsequently, the theoretical expectation of the ozone generation inside the investigated reactors should be extended to take the ozone destruction processes into account.…”
Section: Expectation Of the Ozone Concentration Generated By Silementioning
confidence: 99%
See 1 more Smart Citation
“…The air flowing from outlet of the reactor has been passed through a quartz cell installed in UV-VIS spectrophotometer (SHIMADZU-1200), where the absorbance of the ozone was recorded at a wavelength of 253.7 nm. [22][23][24][25] The ozone concentration [O3] in the flowing air was calculated from the absorbance measurements by using Beer-Lambert law. 6 The average room temperature during the experimental measurements was about 288 K. Every point of the experimental results represents the mean of three independent readings under the same operating conditions.…”
Section: B Measuring Techniquementioning
confidence: 99%
“…Subsequently, two of the authors of this paper have studied previously the ozone generation with the corona discharges under different operating conditions. [22][23][24][25] From another point of view, single wire-duct arrangement is being used over a wide range as discharge electrodes in the electrostatic precipitators. [26][27][28][29] Therefore, the corona discharges were studied in this paper inside dry air fed single wire-duct reactor under positive dc voltage.…”
Section: Introductionmentioning
confidence: 99%