2018
DOI: 10.3390/en11040737
|View full text |Cite
|
Sign up to set email alerts
|

Calculation of Equivalent Resistance for Ground Wires Twined with Armor Rods in Contact Terminals

Abstract: Ground wire breakage accidents can destroy the stable operation of overhead lines. The excessive temperature increase arising from the contact resistance between the ground wire and armor rod in the contact terminal is one of the main reasons causing the breakage of ground wires. Therefore, it is necessary to calculate the equivalent resistance for ground wires twined with armor rods in contact terminals. According to the actual distribution characteristics of the contact points in the contact terminal, a thre… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 25 publications
0
5
0
Order By: Relevance
“…The FEA model of ACSR is verified by the temperature rise experiments of a 15 m new conductor [ 23 ]. The conductor is formed into a closed loop by a parallel groove clamp, and part of it (length of 1.5 m) is set in a closed wind tunnel, as shown in figure 7 a .…”
Section: Finite-element Analysis Calculation For Aluminium Conductor Steel Reinforced Temperaturementioning
confidence: 99%
“…The FEA model of ACSR is verified by the temperature rise experiments of a 15 m new conductor [ 23 ]. The conductor is formed into a closed loop by a parallel groove clamp, and part of it (length of 1.5 m) is set in a closed wind tunnel, as shown in figure 7 a .…”
Section: Finite-element Analysis Calculation For Aluminium Conductor Steel Reinforced Temperaturementioning
confidence: 99%
“…To support the ice loads and predict ice cover thickness, physical methods [12], empirical methods [13,14], and intelligent methods [15] were introduced. The stable operation of overhead lines affected by ground wire breakage accidents was discussed in [16]. A technique for modelling ice storms was developed in [17], which was also applied to evaluate the impact of ice storms on the Swedish transmission network.…”
Section: Introductionmentioning
confidence: 99%
“…A number of methods have been employed to calculate the contact resistance in the literature including finite element analysis (FEA), experimental measurement, and electrical contacts model analysis (ECMA) [8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26]. In the FEA method, some researchers have added an extremely thin film on the contact interface of the two connectors.…”
Section: Introductionmentioning
confidence: 99%
“…The actual contact condition was then simulated by changing the material properties of the film [8,9]. Other researchers have adopted a number of tiny conductive bridges on the contact interface to simulate the contact condition [10][11][12]. The electric-thermal coupling model of the cable joint was also established for assessing its hot spot and ampacity [13,14].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation