1999
DOI: 10.1088/0031-9155/44/12/305
|View full text |Cite
|
Sign up to set email alerts
|

Calculation of a pencil beam kernel from measured photon beam data

Abstract: Usually, pencil beam kernels for photon beam calculations are obtained by Monte Carlo calculations. In this paper, we present a method to derive a pencil beam kernel from measured beam data, i.e. central axis depth doses, phantom scatter factors and off-axis ratios. These data are usually available in a radiotherapy planning system. The differences from other similar works are: (a) the central part of the pencil beam is derived from the measured penumbra of large fields and (b) the dependence of the primary ph… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
51
0

Year Published

2005
2005
2017
2017

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 87 publications
(53 citation statements)
references
References 17 publications
2
51
0
Order By: Relevance
“…The output factor measurement results were daisy‐chained, as presented by Dieterich et al (24) The PBC algorithm is an analytical correction‐based algorithm where the dose is calculated by convoluting the field intensity fluence with narrow pencil beam kernels. Subsequently, corrections for patient surface obliquity and heterogeneities are performed 25 , 26 , 27 . The AAA is a semi‐analytical, model‐based algorithm, although its core is built on exploiting pencil beams.…”
Section: Methodsmentioning
confidence: 99%
“…The output factor measurement results were daisy‐chained, as presented by Dieterich et al (24) The PBC algorithm is an analytical correction‐based algorithm where the dose is calculated by convoluting the field intensity fluence with narrow pencil beam kernels. Subsequently, corrections for patient surface obliquity and heterogeneities are performed 25 , 26 , 27 . The AAA is a semi‐analytical, model‐based algorithm, although its core is built on exploiting pencil beams.…”
Section: Methodsmentioning
confidence: 99%
“…Dose calculations were performed using version 7.5.18 of the Eclipse Dose Calculation Server, using a 2.5mm calculation grid. Calculations performed with the system's older Pencil Beam Convolution algorithm [23] for comparison used the same grid size and an Equivalent Tissue-Air Ratio (ETAR) inhomogeneity correction, in line with current practice at our institution.…”
Section: Equipment Usedmentioning
confidence: 99%
“…This has been carried out by two different groups. 9,[15][16][17][18][19] They fitted the polyenergetic pencil beam kernel to an analytical expression according to experimental data usually measured during the commissioning procedure.…”
Section: Introductionmentioning
confidence: 99%