2016
DOI: 10.1016/j.ejso.2016.02.250
|View full text |Cite
|
Sign up to set email alerts
|

Calculating regional tissue volume for hyperthermic isolated limb perfusion: Four methods compared

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 17 publications
0
4
0
Order By: Relevance
“…Image acquisition parameters included: voltage of 120 kV, X-ray tube current 40–160 mA with an exposure time of 505 ms. In this study, only HUs representing fat in the CT scans were targeted based on the range − 150 to − 50 HU, as defined in previous studies 1 , 4 , 8 . The regions of interest (ROIs) were applied to the patient series when it was processed using VolSEQ to act as a boundary to only quantify pixels in the PSIJ area of the image using pre-made ROIs.…”
Section: Methodsmentioning
confidence: 99%
“…Image acquisition parameters included: voltage of 120 kV, X-ray tube current 40–160 mA with an exposure time of 505 ms. In this study, only HUs representing fat in the CT scans were targeted based on the range − 150 to − 50 HU, as defined in previous studies 1 , 4 , 8 . The regions of interest (ROIs) were applied to the patient series when it was processed using VolSEQ to act as a boundary to only quantify pixels in the PSIJ area of the image using pre-made ROIs.…”
Section: Methodsmentioning
confidence: 99%
“…VolSEQ is intended to help quantify pixels of selected tissue based on a known range of Houns eld units (HU) on conventional CT scans (SOMATOM as64 open, Siemens, Munich, Germany; Aquilion one, Toshiba, Tokyo, Japan). In this study, only HUs representing fat in the CT scans were targeted based on the range − 150 to − 50 HU, as de ned in previous studies 1,4,8 . The regions of interest (ROIs) were applied to the patient series when it was processed using VolSEQ to act as a boundary to only quantify pixels in the PSIJ area of the image using pre-made ROIs.…”
Section: Fat Quanti Cation Using Volseqmentioning
confidence: 99%
“…Quanti cation of tissue volumes and subvolumes using medical imaging techniques is not a new technique [1][2][3][4][5][6][7][8] . Commonly, data sets derived from magnetic resonance imaging (MRI) 2,9−15 or computed tomography (CT) are used for this purpose.…”
Section: Introductionmentioning
confidence: 99%
“…Current hyperthermia strategies generally include local, regional, and whole-body approaches. Several technologies are used, such as microwave, radiofrequency, laser, ultrasound [3] and extracorporeal circulation [4]. For example, intraperitoneal hyperthermic chemotherapy (HIPEC) has been proposed for enhancing the cytotoxic effect of cytostatic drugs on peritoneal malignancies [5].…”
mentioning
confidence: 99%