2008
DOI: 10.1016/j.cvsm.2008.01.010
|View full text |Cite
|
Sign up to set email alerts
|

Calcium: Total or Ionized?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
45
0
1

Year Published

2012
2012
2013
2013

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 34 publications
(48 citation statements)
references
References 19 publications
2
45
0
1
Order By: Relevance
“…Careful attention to technique is important; the process of collecting a sample for ionized calcium should be as ‘anaerobic' as possible. Blood should be collected directly into a serum heparinized Vacutainer tube as those containing oxalate, citrate or ethylenediaminetetraacetic acid (EDTA) can decrease the calcium available for analysis due to these chemicals binding to it [6]. If a syringe is used, a premeasured quantity of dry heparin is preferable to manually coating the syringe with liquid heparin, which can dilute the sample and falsely decrease the measured ionized calcium.…”
Section: Measurement Of Calciummentioning
confidence: 99%
“…Careful attention to technique is important; the process of collecting a sample for ionized calcium should be as ‘anaerobic' as possible. Blood should be collected directly into a serum heparinized Vacutainer tube as those containing oxalate, citrate or ethylenediaminetetraacetic acid (EDTA) can decrease the calcium available for analysis due to these chemicals binding to it [6]. If a syringe is used, a premeasured quantity of dry heparin is preferable to manually coating the syringe with liquid heparin, which can dilute the sample and falsely decrease the measured ionized calcium.…”
Section: Measurement Of Calciummentioning
confidence: 99%
“…Overall, however, electrolyte analysis should be performed on serum samples that are col lected anaerobically. 3,4,[8][9][10][11] Anaerobic conditions are most important for ionized calcium and magnesium analysis. 4,10-12 Whole blood, anticoagulated whole blood, and plasma can also be used, but one must consider various possible artifacts and the risk of clot formation prior to the completion of analysis when using whole blood.…”
Section: Methods Of Electrolyte Quantificationmentioning
confidence: 99%
“…11,37 These formulas have since been shown to cause spurious interpretation of calcium levels in the face of hypoproteinemia. 11,37 Total calcium measurements correlate poorly with ionized calcium in situations of renal insufficiency and acidbase imbal ance. 4,12 Total calcium measurement can also be spuri ously affected by hemolysis, hyperbilirubinemia, and lipemia.…”
Section: Calcium Concentration Measurementmentioning
confidence: 99%
See 2 more Smart Citations