1998
DOI: 10.1177/107110079801900703
|View full text |Cite
|
Sign up to set email alerts
|

Bunion Correction Using Proximal Chevron Osteotomy: A Single-Incision Technique

Abstract: Proximal chevron first metatarsal osteotomy with lateral capsulotomy, adductor tenotomy, and binding of the first and second metatarsals was reviewed in 88 consecutive cases. Seventy-two cases in 55 patients are reported, with an average clinical follow-up of 41 months. The hallux valgus angle improved an average of 15 degrees , from 32.0 degrees preoperatively to an average of 17.0 degrees postoperatively. The intermetatarsal I-II angle improved an average of 5.5 degrees, from 15.3 degrees preoperatively to 9… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

4
50
0
5

Year Published

2003
2003
2014
2014

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 73 publications
(59 citation statements)
references
References 41 publications
4
50
0
5
Order By: Relevance
“…The gap becomes even greater when the supination is added to the angulation. Therefore, various fixation methods, such as Kirschner wires, screws, and plates have been used to stabilise the osteotomy [3][4][5][6].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The gap becomes even greater when the supination is added to the angulation. Therefore, various fixation methods, such as Kirschner wires, screws, and plates have been used to stabilise the osteotomy [3][4][5][6].…”
Section: Discussionmentioning
confidence: 99%
“…However, transfer metatarsalgia often occurs due to the long moment arm of the distal fragment and insecure fixation. Accordingly, several different methods have been introduced to enhance the stability of the fixation [3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…The large contact area is relatively stable, and for fixation a combination of a screw and a Kirschner wire, two screws, or a plate are recommended [2,[9][10][11][12][13][14][15][16][17]. Nevertheless, relatively high rates of dorsiflexion malunion of up to 17 % are reported for this procedure.…”
Section: Introductionmentioning
confidence: 99%
“…The proximal chevron osteotomy, first reported by Sammarco et al, does not simply rely on a lateral translation of the distal fragment, as with the distal chevron procedure [9] but concomitantly incorporates an opening wedge principle [9][10][11]. The large contact area is relatively stable, and for fixation a combination of a screw and a Kirschner wire, two screws, or a plate are recommended [2,[9][10][11][12][13][14][15][16][17].…”
Section: Introductionmentioning
confidence: 99%
“…However, we found several repeated studies in the meta-analysis ( included all these studies in their meta-analysis. In our opinion, some repeated data might exist among their studies [2][3][4][5][6][7]. To solve these problems, we suggest that these studies [2,4,6] should be excluded from the meta-analysis.…”
mentioning