2009 Third International Conference on Network and System Security 2009
DOI: 10.1109/nss.2009.82
|View full text |Cite
|
Sign up to set email alerts
|

Building a SCADA Security Testbed

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
40
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 76 publications
(40 citation statements)
references
References 8 publications
0
40
0
Order By: Relevance
“…As shown in Figure 2, the Modbus/TCP packet format [26] mainly includes three parts: MBAP packet header, Modbus function code, and data.…”
Section: Feature Extraction and Data Preprocessingmentioning
confidence: 99%
“…As shown in Figure 2, the Modbus/TCP packet format [26] mainly includes three parts: MBAP packet header, Modbus function code, and data.…”
Section: Feature Extraction and Data Preprocessingmentioning
confidence: 99%
“…However, the high fidelity of this testing environment is counterbalanced by its poor flexibility and the high cost of maintenance of a similar architecture. Another approach that uses real physical devices was proposed by Queiroz, et al [9]. In this case only the sensors and actuators are real physical devices, while the remaining components such as PLCs, and the communications protocols between them are implemented as OMNeT++ modules.…”
Section: Related Workmentioning
confidence: 99%
“…In the same category we find the work of Hiyama and Ueno [13] The present work builds on the advantages of the previously mentioned methods. For the physical part, instead of using real components as was the case of [7], [8] and [9], it uses simulation. This provides an efficient, safe and low-cost approach with fast and accurate analysis capabilities.…”
Section: Related Workmentioning
confidence: 99%
See 1 more Smart Citation
“…Although from one point of view such a testbed would provide reliable experimental data, since almost everything is real, it would be hardly able to support tests on large infrastructures such as the process system of a chemical installation, because that would require a complete industrial system to experiment with. Another approach that uses real physical devices has been proposed by Queiroz, et al [5]. In this case only the sensors and actuators are real physical devices, while the remaining components, e.g., PLCs, and the communication protocols between them are implemented as OMNeT++ modules.…”
Section: Related Workmentioning
confidence: 99%