2022
DOI: 10.5797/jnet.tn.2022-0005
|View full text |Cite
|
Sign up to set email alerts
|

Buddy Catheter Technique: A Method of Guiding the Mo.Ma Ultra into a Left Common Carotid Artery That Branches off the Aortic Arch at a Steep Angle

Abstract: Objective The Mo.Ma Ultra is an embolic protection device used in carotid artery stenting (CAS). In cases of left internal carotid artery stenosis (ICS) in which the common carotid artery (CCA) branches off the aortic arch at a steep angle, insertion of the Mo.Ma Ultra into the CCA is sometimes difficult. We introduce a “buddy catheter technique” that helps guide the Mo.Ma Ultra into the CCA, with an additional 4 Fr catheter into the external carotid artery. Case Presentation … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 9 publications
0
2
0
Order By: Relevance
“…Conversely, CSs allow for aortic arch adjustments, and most angles between the LSA and the aortic arch can be accommodated, thereby increasing the applicability of the technique and enhancing surgical success rates. In some patients with a steep aortic arch, the ISFs technique has certain limitations, particularly the insufficient anchorage distance of the main stent graft 23 . Insufficient anchorage distance necessitates moving the main stent graft forward, potentially covering or partially covering the left common carotid artery, which may affect its flow 24 .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Conversely, CSs allow for aortic arch adjustments, and most angles between the LSA and the aortic arch can be accommodated, thereby increasing the applicability of the technique and enhancing surgical success rates. In some patients with a steep aortic arch, the ISFs technique has certain limitations, particularly the insufficient anchorage distance of the main stent graft 23 . Insufficient anchorage distance necessitates moving the main stent graft forward, potentially covering or partially covering the left common carotid artery, which may affect its flow 24 .…”
Section: Discussionmentioning
confidence: 99%
“…In some patients with a steep aortic arch, the ISFs technique has certain limitations, particularly the insufficient anchorage distance of the main stent graft. 23 Insufficient anchorage distance necessitates moving the main stent graft forward, potentially covering or partially covering the left common carotid artery, which may affect its flow. 24 Notably, CSs have a variety of models, and an appropriate stent type can be chosen according to the morphology of the LSA and aortic arch, greatly increasing adaptability and surgical success rates.…”
Section: Discussionmentioning
confidence: 99%