2006
DOI: 10.1016/j.mineng.2005.09.002
|View full text |Cite
|
Sign up to set email alerts
|

Bubble size as a function of impeller speed in a self-aeration laboratory flotation cell

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
20
0
1

Year Published

2007
2007
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 48 publications
(22 citation statements)
references
References 8 publications
1
20
0
1
Order By: Relevance
“…Bubbles rose into the viewing chamber and were imaged by a digital camera as they slid up the inclined window, which was illuminated from behind. In this research, at first, frother was added to the water of the cell and then the viewing chamber was filled with water of the cell to prevent bubble coalescence [25].…”
Section: Methodsmentioning
confidence: 99%
“…Bubbles rose into the viewing chamber and were imaged by a digital camera as they slid up the inclined window, which was illuminated from behind. In this research, at first, frother was added to the water of the cell and then the viewing chamber was filled with water of the cell to prevent bubble coalescence [25].…”
Section: Methodsmentioning
confidence: 99%
“…The closed assembly is filled with water of similar nature to that in the flotation cell (to limit changes in bubble environment during sampling) and the tube is immersed to the desired location below the froth. Bubble raise into the viewing chamber and are imaged by a digital photo camera as they slide up the inclined window illuminated from behind [17].…”
Section: Methodsmentioning
confidence: 99%
“…In this research, bubble size distribution was measured similar to McGill bubble viewer [17]. The mean bubble diameter adopted was the Sauter diameter, calculated by the equation below [18]:…”
Section: Bubble Size Distributionmentioning
confidence: 99%
“…At the froth-pulp interface, gas bubbles with attached particles are transferred from the pulp zone to the froth layer at the rate bubbles arrive at the interface. Based on bubble size measurements in air-water system with frother addition (Girgin et al, 2006), an average diameter of 1 mm is applied in the model.…”
Section: Model Descriptionmentioning
confidence: 99%
“…The air flow rates predicted by CFD are compared against measured values reported in the literature for this cell (Girgin et al, 2006).…”
Section: Introductionmentioning
confidence: 99%