2020
DOI: 10.1183/23120541.00146-2020
|View full text |Cite
|
Sign up to set email alerts
|

Bronchoscopically delivered microwave ablation in anin vivoporcine lung model

Abstract: BackgroundPercutaneous microwave ablation is clinically used for inoperable lung tumour treatment. Delivery of microwave ablation applicators to tumour sites within lung parenchyma under virtual bronchoscopy guidance may enable ablation with reduced risk of pneumothorax, providing a minimally invasive treatment of early-stage tumours, which are increasingly detected with computed tomography (CT) screening. The objective of this study was to integrate a custom microwave ablation platform, incorporating a flexib… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 20 publications
(21 citation statements)
references
References 41 publications
0
17
0
Order By: Relevance
“…Most of the thermal ablative techniques in literature applied the electrode in a percutaneous manner. Lately, transbronchial ablation techniques using different energy source have been researched in animal lung models (24)(25)(26). In humans, bronchoscopy-guided transbronchial ablation have been attempted by a Japanese and a Chinese group, utilizing RFA energy with reported safety (27)(28)(29).…”
Section: Discussionmentioning
confidence: 99%
“…Most of the thermal ablative techniques in literature applied the electrode in a percutaneous manner. Lately, transbronchial ablation techniques using different energy source have been researched in animal lung models (24)(25)(26). In humans, bronchoscopy-guided transbronchial ablation have been attempted by a Japanese and a Chinese group, utilizing RFA energy with reported safety (27)(28)(29).…”
Section: Discussionmentioning
confidence: 99%
“…In the present study, we limit applied power to the range 10 W < P < 70 W with 10 W sampling step, as assessed at the catheter tip, and ablation duration to the range 2 < t < 10 min with 1 min sampling step consistent with the anticipated use settings for bronchoscopic microwave ablation. 7 Furthermore, collateral damage values are computed with respect to the maximum evaluated minimum margin, which is 5 mm. The total number of simulations for each [P, t] combination was N = 20 to provide reasonable compromise between sufficient sampling of minimum margin statistical distribution and overall computation time.…”
Section: A Treatment Planning Methodologymentioning
confidence: 99%
“…The MWA applicator modeled in this study is similar to the flexible applicator described in. 7 Briefly, the applicator consists of a 2.45-GHz antenna with a balun, integrated within a custom catheter-extrusion through which chilled water is circulated. The outer diameter of the catheter is 2 mm, and it is suitable for deployment via the instrument channel of a flexible bronchoscope.…”
Section: B Microwave Ablation Applicatormentioning
confidence: 99%
See 2 more Smart Citations