1989
DOI: 10.1093/ajcn/50.1.168
|View full text |Cite
|
Sign up to set email alerts
|

Bromide space determination using anion-exchange chromatography for measurement of bromide

Abstract: A high-pressure liquid chromatographic method for bromide measurement is used to determine extracellular water volume in humans. The method uses 5 microL serum ultrafiltrate and has a sensitivity of 7.5 pmol. Because of the extreme sensitivity of this method, relatively small quantities of Br can be administered and small amounts of blood are needed for the analysis. By this method, the mean corrected Br space in 82 healthy adults representing a wide range of body weights was 0.218 +/- .034 L/kg (mean +/- 1 SD… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
64
0

Year Published

1991
1991
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 118 publications
(65 citation statements)
references
References 12 publications
1
64
0
Order By: Relevance
“…BCM was measured using isotope dilution with correction for extracellular water, measured by bromide dilution as previously described. [19][20][21] BCM was calculated based on the assumption that intracellular water constitutes 73.2% of BCM, 22 and calculation of intracellular water was based on the difference between total body water and extracellular water. Total body water was determined using H 2 18 O as a tracer (Cambridge Isotopes, Cambridge, MA), described by Schoeller et al 19 Extracellular water was determined through bromide (Sigma Chemical Corp, St Louis, MO) dilution, described previously by Miller et al 20 BCM values were normalized for height.…”
Section: Methodsmentioning
confidence: 99%
“…BCM was measured using isotope dilution with correction for extracellular water, measured by bromide dilution as previously described. [19][20][21] BCM was calculated based on the assumption that intracellular water constitutes 73.2% of BCM, 22 and calculation of intracellular water was based on the difference between total body water and extracellular water. Total body water was determined using H 2 18 O as a tracer (Cambridge Isotopes, Cambridge, MA), described by Schoeller et al 19 Extracellular water was determined through bromide (Sigma Chemical Corp, St Louis, MO) dilution, described previously by Miller et al 20 BCM values were normalized for height.…”
Section: Methodsmentioning
confidence: 99%
“…ECW (DIL) was determined as bromide space, modified after Miller et al, (1989). After 3 h of equilibration, a blood sample was drawn, serum was separated and stored at 7 20 C until analysis.…”
Section: Body Composition Analysismentioning
confidence: 99%
“…After 3 h of equilibration, a blood sample was drawn, serum was separated and stored at 7 20 C until analysis. Samples were deproteinised using methanol and after subsequent centrifugation, bromide concentration was determined by high performance ion chromatography (HPIC, Dionex ion-chromatographic The correction factor for non-extracellular distribution of Br ¼ 0.90, and correction for the Donnan equilibrium ¼ 0.95 (Miller et al, 1989).…”
Section: Body Composition Analysismentioning
confidence: 99%
“…The ECW compartment was determined by bromide dilution, and the bromide concentration was determined from serum after a 10-hour fast. Corrected bromide space was calculated according to the method of Miller et al 29 ICW is calculated by subtracting ECW from TBW. …”
Section: Extracellular Watermentioning
confidence: 99%