2000
DOI: 10.1002/1522-726x(200012)51:4<483::aid-ccd24>3.0.co;2-f
|View full text |Cite
|
Sign up to set email alerts
|

Broken guidewire fragment: A simplified retrieval technique

Abstract: We report a technique for retrieval of a broken angioplasty wire fragment from the coronary system using a more simplified technique that does not involve the use of a snare or any other retrieval tool. With the use of an additional angioplasty wire and a balloon catheter, we could safely remove the broken wire fragment from the coronary system and circulation in a very short time.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
26
0
6

Year Published

2002
2002
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 43 publications
(32 citation statements)
references
References 5 publications
0
26
0
6
Order By: Relevance
“…Several percutaneous techniques used for retrieval of entrapped guide-wire fragments including stenting against the vessel wall (7 cases) [12, 15-19], snare loop (9 cases) [1, 20-25], double or triple wire technique (3 cases) [7, 26, 27], bioptome (1 case) [1], tornus micro-catheter (1 case) [28], deep-guide catheter wedging with balloon inflation (6 cases) [1, 3, 29, 30] and pigtail catheter (1 case) [6]. …”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Several percutaneous techniques used for retrieval of entrapped guide-wire fragments including stenting against the vessel wall (7 cases) [12, 15-19], snare loop (9 cases) [1, 20-25], double or triple wire technique (3 cases) [7, 26, 27], bioptome (1 case) [1], tornus micro-catheter (1 case) [28], deep-guide catheter wedging with balloon inflation (6 cases) [1, 3, 29, 30] and pigtail catheter (1 case) [6]. …”
Section: Resultsmentioning
confidence: 99%
“…This is a method used if the wire is still intact and the guide is over-wedged, then the balloon is advanced and inflated at the terminal part of the guide catheter and is tightly trapping the wire and the whole system is retracted to pull out the retained wire [1, 3, 29, 30]. Another method to free the retained wire is the use of tornus micro-catheter, in which the micro-catheter is advanced with particular rotations to the tip of the wire to allow for the release of the jailed or entrapped part [28].…”
Section: Management Strategies Of Retained Guide Wire Remnantsmentioning
confidence: 99%
“…Furthermore, fracture, migration, and entrapment of 0.035-inch large diameter wire is extremely rare. Some reports have considered removal techniques for fractured guide wires in the coronary artery 2)4)8). These guide wires were always the 0.014-inch usual coronary guide wires, but this is the first report regarding successful retrieval of a fractured 0.035-inch guide wire.…”
Section: Discussionmentioning
confidence: 99%
“…The incidence of retained components of percutaneous angioplasty equipment is reported to be 0.2% in single-centre series 3. The successful recovery of balloons and guide wire fragments uses techniques similar to those for retrieving embolised stents 4 5…”
Section: Device Embolisationmentioning
confidence: 99%